The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements
Open accessAbstract
The accuracy of the nonlinear one-dimensional (1-D) equations of pressure and flow wave propagation in Voigt-type visco-elastic arteries was tested against measurements in a well-defined experimental 1:1 replica of the 37 largest conduit arteries in the human systemic circulation. The parameters required by the numerical algorithm were directly measured in the in vitro setup and no data fitting was involved. The inclusion of wall visco-elasticity in the numerical model reduced the underdamped high-frequency oscillations obtained using a purely elastic tube law, especially in peripheral vessels, which was previously reported in this paper [Matthys et al., 2007. Pulse wave propagation in a model human arterial network: Assessment of 1-D numerical simulations against in vitro measurements. J. Biomech. 40, 3476-3486]. In comparison to the purely elastic model, visco-elasticity significantly reduced the average relative root-mean-square errors between numerical and experimental waveforms over the 70 locations measured in the in vitro model: from 3.0% to 2.5% (p<0.012) for pressure and from 15.7% to 10.8% (p<0.002) for the flow rate. In the frequency domain, average relative errors between numerical and experimental amplitudes from the 5th to the 20th harmonic decreased from 0.7% to 0.5% (p<0.107) for pressure and from 7.0% to 3.3% (p<10(-6)) for the flow rate. These results provide additional support for the use of 1-D reduced modelling to accurately simulate clinically relevant problems at a reasonable computational cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Cruickshank, K., Riste, L., Anderson, S. G., Wright, J. S., Dunn, G., & Gosling, R. G. (2002) · Circulation · doi:10.1161/01.cir.0000033824.02722.f7 · Cited by 1,531
Spectral/hp Element Methods for Computational Fluid Dynamics
Karniadakis, G., & Sherwin, S. (2005) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780198528692.001.0001 · Cited by 1,473
Self-citationThe Mechanics of the Circulation
Caro, C. G., Pedley, T. J., Schroter, R. C., Seed, W. A., & Parker, K. H. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139013406 · Cited by 912
Self-citationOlufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638
Computer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511
One-dimensional models for blood flow in arteries
Formaggia, L., Lamponi, D., & Quarteroni, A. M. (2003) · Journal of Engineering Mathematics · doi:10.1023/b:engi.0000007980.01347.29 · Cited by 500
Computational vascular fluid dynamics: problems, models and methods
Quarteroni, A., Tuveri, M., & Veneziani, A. (2000) · Computing and Visualization in Science · doi:10.1007/s007910050039 · Cited by 480
Cited by
An introduction to wave intensity analysis
Parker, K. H. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0439-y · Cited by 309
Self-citationAssessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131
Self-citation
Metadata
- Authors
- Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2011-08
- Volume
- 44
- Issue
- 12
- Pages
- 2250-2258
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2111599533
- Cited by
- 441
- References
- 40
- FWCI
- 16.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements. https://app.cochat.ai/papers/10.1016/j.jbiomech.2011.05.041
- The paper
- Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J. (2011). Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2011.05.041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.