The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Confocal Microscopy: Principles and Modern Practices
Open accessAbstract
In light microscopy, illuminating light is passed through the sample as uniformly as possible over the field of view. For thicker samples, where the objective lens does not have sufficient depth of focus, light from sample planes above and below the focal plane will also be detected. The out‐of‐focus light will add blur to the image, reducing the resolution. In fluorescence microscopy, any dye molecules in the field of view will be stimulated, including those in out‐of‐focus planes. Confocal microscopy provides a means of rejecting the out‐of‐focus light from the detector such that it does not contribute blur to the images being collected. This technique allows for high‐resolution imaging in thick tissues. In a confocal microscope, the illumination and detection optics are focused on the same diffraction‐limited spot in the sample, which is the only spot imaged by the detector during a confocal scan. To generate a complete image, the spot must be moved over the sample and data collected point by point. A significant advantage of the confocal microscope is the optical sectioning provided, which allows for 3D reconstruction of a sample from high‐resolution stacks of images. Several types of confocal microscopes have been developed for this purpose, and each has different advantages and disadvantages. This article provides a concise introduction to confocal microscopy. © 2019 by John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
A guide to choosing fluorescent proteins
Shaner, N. C., Steinbach, P. A., & Tsien, R. Y. (2005) · Nature Methods · doi:10.1038/nmeth819 · Cited by 2,840
Lichtman, J. W., & Conchello, J.-A. (2005) · Nature Methods · doi:10.1038/nmeth817 · Cited by 1,742
Memoir on inventing the confocal scanning microscope
Minsky, M. (1988) · Scanning · doi:10.1002/sca.4950100403 · Cited by 1,118
Spectral imaging and its applications in live cell microscopy
Zimmermann, T., Rietdorf, J., & Pepperkok, R. (2003) · FEBS Letters · doi:10.1016/s0014-5793(03)00521-0 · Cited by 536
A Critical and Comparative Review of Fluorescent Tools for Live-Cell Imaging
Specht, E. A., Braselmann, E., & Palmer, A. E. (2017) · Annual Review of Physiology · doi:10.1146/annurev-physiol-022516-034055 · Cited by 444
Inoué, S., & Spring, K. R. (1997) · doi:10.1007/978-1-4615-5859-0 · Cited by 326
Seeing is believing? A beginners' guide to practical pitfalls in image acquisition
North, A. J. (2006) · Journal of Cell Biology · doi:10.1083/jcb.200507103 · Cited by 257
Re-scan confocal microscopy: scanning twice for better resolution
De Luca, G. M. R., Breedijk, R. M. P., Brandt, R. A. J., Zeelenberg, C. H. C., de Jong, B. E., Timmermans, W., Azar, L. N., Hoebe, R. A., Stallinga, S., & Manders, E. M. M. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.002644 · Cited by 225
Multi-photon excitation microscopy
Diaspro, A., Bianchini, P., Vicidomini, G., Faretta, M., Ramoino, P., & Usai, C. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-36 · Cited by 185
Fluorescence Microscopy: A Concise Guide to Current Imaging Methods
Combs, C. A., & Shroff, H. (2017) · Current Protocols in Neuroscience · doi:10.1002/cpns.29 · Cited by 184
Laser Scanning Confocal Microscopy: History, Applications, and Related Optical Sectioning Techniques
Paddock, S. W., & Eliceiri, K. W. (2013) · Methods in molecular biology · doi:10.1007/978-1-60761-847-8_2 · Cited by 104
Confocal Microscopy for Biologists
Hibbs, A. R. (2004) · Springer eBooks · doi:10.1007/978-0-306-48565-7 · Cited by 102
Fluorescence microscopy - avoiding the pitfalls
Brown, C. M. (2007) · Journal of Cell Science · doi:10.1242/jcs.03433 · Cited by 86
Evaluation of seven optical clearing methods in mouse brain
Wan, P., Zhu, J., Xu, J., Li, Y., Yu, T., & Zhu, D. Y. (2018) · Neurophotonics · doi:10.1117/1.nph.5.3.035007 · Cited by 85
Live-Cell Fluorescence Imaging
Waters, J. C. (2013) · Methods in cell biology · doi:10.1016/b978-0-12-407761-4.00006-3 · Cited by 53
Recent developments of genetically encoded optical sensors for cell biology
Bolbat, A., & Schultz, C. (2016) · Biology of the Cell · doi:10.1111/boc.201600040 · Cited by 48
Ribbon scanning confocal for high-speed high-resolution volume imaging of brain
Watson, A. M., Rose, A. H., Gibson, G. A., Gardner, C. L., Sun, C., Reed, D. S., Lam, L., Croix, C. M. S., Strick, P. L., Klimstra, W. B., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0180486 · Cited by 37
Fluorescent probes for nanoscopy: four categories and multiple possibilities
Ni, M., Zhuo, S., So, P. T. C., & Yu, H. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201600042 · Cited by 32
Smith, C. L. (2008) · Current Protocols in Molecular Biology · doi:10.1002/0471142727.mb1411s81 · Cited by 25
Metadata
- Authors
- Elliott, A. D.
- Venue
- Current Protocols in Cytometry
- Publisher
- Wiley
- Published
- 2019-12-26
- Volume
- 92
- Issue
- 1
- Pages
- e68-e68
- ISSN
- 1934-9297 (ISSN-L)
- 1934-9300
- OpenAlex
- W2997051184
- Cited by
- 438
- References
- 24
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.