Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index; none of the 42 sources its claims cite is checked for support yet.

PHRONESIS: A One‐Shot Approach for Sequential Assignment of Protein Resonances by Ultrafast MAS Solid‐State NMR Spectroscopy

Open access

Abstract

Solid‐state NMR (ssNMR) spectroscopy has emerged as the method of choice to analyze the structural dynamics of fibrillar, membrane‐bound, and crystalline proteins that are recalcitrant to other structural techniques. Recently, 1 H detection under fast magic angle spinning and multiple acquisition ssNMR techniques have propelled the structural analysis of complex biomacromolecules. However, data acquisition and resonance‐specific assignments remain a bottleneck for this technique. Here, we present a comprehensive multi‐acquisition experiment (PHRONESIS) that simultaneously generates up to ten 3D 1 H‐detected ssNMR spectra. PHRONESIS utilizes broadband transfer and selective pulses to drive multiple independent polarization pathways. High selectivity excitation and de‐excitation of specific resonances were achieved by high‐fidelity selective pulses that were designed using a combination of an evolutionary algorithm and artificial intelligence. We demonstrated the power of this approach with microcrystalline U‐13 C,15 N GB1 protein, reaching 100 % of the resonance assignments using one data set of ten 3D experiments. The strategy outlined in this work opens up new avenues for implementing novel 1 H‐detected multi‐acquisition ssNMR experiments to speed up and expand the application to larger biomolecular systems.

Overview

CoChat Summary

TL;DR

PHRONESIS is a multi-acquisition 1H-detected ultrafast MAS solid-state NMR experiment that simultaneously generates up to ten 3D spectra for protein backbone sequential assignment. Applied to U-13C,15N microcrystalline GB1, it achieved complete resonance assignment in 52 h, about 50% less time than conventional 3D experiments (~103 h).

Key findings

  • PHRONESIS combines broadband SIM-CP/SPECIFIC-CP, GENETICS-AI selective pulses, and Hadamard encoding to create ten 3D spectra; the selective pulses had fidelity >0.99, with a CO excitation pulse of 59 μs at constant 16.7 kHz RF amplitude.
  • For GB1, the 3D spectra unambiguously resolved 60–80% of resonances; using only the (H)CANH-(H)CA(CO)NH pair gave 36% correct NH spin-system assignments, but including CO(i−1) and CO(i) correlations from (H)CONH and (H)CO(CA)NH reached 100% accuracy.
  • Total experimental time was 52 h versus ~103 h for conventional 3D experiments, a net ~50% saving; PHRONESIS (H)CANH 1D intensity was 97% relative to conventional, while other pathways ranged from 20–75% and HH cross-peak spectra were 6–10%.
  • HA assignments were obtained for 30 residues: 18 from (H)CAN(HN)H, 17 from (H)CON(HN)H, and 5 in both; an additional 15 HN peaks were resolved but their HA peaks were not detected.

Methods

  • Sample: U-13C,15N labeled microcrystalline GB1 (β1 immunoglobulin binding domain of protein G, crystal form A), ~2 mg packed into a 1.3 mm rotor; experiments on a Bruker 600 MHz spectrometer with a 1.3 mm fast MAS probe at 65 kHz MAS and 25 °C sample temperature (RF coil set to −18 °C).
  • Pulse sequence: four 1H acquisition periods; SIM-CP transfers polarization to CA, CO, and 15N; GENETICS-AI selective CA/CO pulses; SPECIFIC-CP and DREAM transfers; Hadamard phase encoding with 16-step encoding and 32 scans; 2 ms z-filter; t1/t2 acquired in States-TPPI.
  • Analysis: data processed with TOPSPIN/NMRPipe and assigned with NMRFAM-SPARKY and the I-PINE server; assignments were compared to previously published assignments; HA assignment used BMRB residue-specific ranges; experimental time estimated as Texp conventional = k² × [Texp PHRONESIS] × 0.97.

Limitations

  • Stated: application to heterogeneous systems such as membrane proteins reconstituted in fully hydrated lipid bilayers will be more challenging because 1H-detected resolution is limited by broadening from conformational dynamics and sample heterogeneity/static disorder.
  • Stated: the low-sensitivity (H)CAN(HN)H and (H)CON(HN)H data give insignificant net time saving; simultaneous optimization of low- and high-sensitivity experiments is generally not feasible; side-chain 1H shifts were not analyzed due to low signal intensities and spectral overlap; HH-RFDR mixing is non-selective and can produce long-range correlations even at short mixing times, potentially complicating spectral analysis.
  • Evident: the demonstration is limited to one small microcrystalline protein (GB1, ~2 mg), with no membrane or fibrillar systems tested; the N(i−1)/N(i+1) pathway is not implemented in commonly used automated assignment software, so manual resolution may be needed.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1002/cphc.202200127

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 (a) GENETICS‐AI pulse for CO excitation obtained from phase modulation and constant RF amplitude (16.7 kHz) with a total length of 59 μs. (b) During the pulse, evolution of CO and CA magnetization trajectories are projected on the Bloch spheres for the CO excitation and CA refocusing (Figures S1 and S2).
Figure 1 (a) GENETICS‐AI pulse for CO excitation obtained from phase modulation and constant RF amplitude (16.7 kHz) with a total length of 59 μs. (b) During the pulse, evolution of CO and CA magnetization trajectories are projected on the Bloch spheres for the CO excitation and CA refocusing (Figures S1 and S2).CC BY · PubMed Central
Figure 2 (a) PHRONESIS experiment for simultaneous acquisition of ten 3D spectra using 1H detected ultrafast MAS. The GENETICS‐AI pulses (gray rectangles) are applied on CA and CO to encode multiple pathways. (c–h) Sequential assignment of GB1 protein using ten 3D spectra (Table S1) acquired with 65 kHz MAS. (h) Summary of unambiguously resolved 3D cross peaks picked from each experiment. Cross peaks obtained from only the (H)CANH‐(H)CA(CO)NH pair yielded correct automatic assignments for only 36 % of NH spin systems, while 100 % accuracy was achieved if CO(i‐1) and CO(i) correlations were also included.
Figure 2 (a) PHRONESIS experiment for simultaneous acquisition of ten 3D spectra using 1H detected ultrafast MAS. The GENETICS‐AI pulses (gray rectangles) are applied on CA and CO to encode multiple pathways. (c–h) Sequential assignment of GB1 protein using ten 3D spectra (Table S1) acquired with 65 kHz MAS. (h) Summary of unambiguously resolved 3D cross peaks picked from each experiment. Cross peaks obtained from only the (H)CANH‐(H)CA(CO)NH pair yielded correct automatic assignments for only 36 % of NH spin systems, while 100 % accuracy was achieved if CO(i‐1) and CO(i) correlations were also included.CC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 20 Not checked · 59 Own results and interpretations

40 more claims

Create a free account to see all 79 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 16
  • It may state two separate claims as one. 22
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 1

  1. Hadamard J., 1893, Bull. Sci. Math., 17, 240

Cited by

Metadata

Authors
Gopinath, T., Manu, V. S., Weber, D. K., & Veglia, G.
Affiliations
University of Minnesota (US)
Corresponding author
  • Gopinath, Tata
  • Veglia, Gianluigi
Venue
ChemPhysChem
Publisher
Wiley
Published
2022-05-19
Volume
23
Issue
13
Pages
e202200127-e202200127
ISSN
  • 1439-4235 (ISSN-L)
  • 1439-7641
OpenAlex
W4225278481
Cited by
12
References
59
Citations by year
2026: 3 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 4
FWCI
0.82
Type
journal article
Language
en
Open access
Locations
  • ChemPhysChem (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
Funders
  • National Institutes of Health (GM 64742, HL144130, 1S10OD021536)
  • American Heart Association (19POST34420009)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
  • Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
Keywords
practical wisdom, microcrystalline proteins, protein structural dynamics
MeSH terms
Algorithms, Artificial Intelligence, Magnetic Resonance Spectroscopy, Proteins, Nuclear Magnetic Resonance, Biomolecular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.