Water irradiation devoid pulses enhance the sensitivity of 1H,1H nuclear Overhauser effects

Open access
Manu, V. S., Olivieri, Cristina, Veglia, Gianluigi · 2023 · Journal of Biomolecular NMR

Abstract

The nuclear Overhauser effect (NOE) is one of NMR spectroscopy's most important and versatile parameters. NOE is routinely utilized to determine the structures of medium-to-large size biomolecules and characterize protein-protein, protein-RNA, protein-DNA, and protein-ligand interactions in aqueous solutions. Typical [1H,1H] NOESY pulse sequences incorporate water suppression schemes to reduce the water signal that dominates 1H-detected spectra and minimize NOE intensity losses due to unwanted polarization exchange between water and labile protons. However, at high- and ultra-high magnetic fields, the excitation of the water signal during the execution of the NOESY pulse sequences may cause significant attenuation of NOE cross-peak intensities. Using an evolutionary algorithm coupled with artificial intelligence, we recently designed high-fidelity pulses [Water irrAdiation DEvoid (WADE) pulses] that elude water excitation and irradiate broader bandwidths relative to commonly used pulses. Here, we demonstrate that WADE pulses, implemented into the 2D [1H,1H] NOESY experiments, increase the intensity of the NOE cross-peaks for labile and, to a lesser extent, non-exchangeable protons. We applied the new 2D [1H,1H] WADE-NOESY pulse sequence to two well-folded, medium-size proteins, i.e., the K48C mutant of ubiquitin and the Raf kinase inhibitor protein (RKIP). We observed a net increase of the NOE intensities varying from 30 to 170% compared to the commonly used NOESY experiments. The new WADE pulses can be easily engineered into 2D and 3D homo- and hetero-nuclear NOESY pulse sequences to boost their sensitivity.

Checked 2026-11-18 · 1 reference not checked yet

Overview

CoChat Summary

TL;DR

WADE (water irradiation devoid) pulses W1F90 and WR4, designed by GENETICS-AI, were incorporated into 2D [1H,1H] NOESY and increased NOE cross-peak intensities in two medium-size proteins relative to standard water-suppression schemes. The reported net NOE intensity gains ranged from 30 to 170%, with larger gains for labile amide protons.

Key findings

  • In UbiK48C, [1H,1H] WADE-NOESY showed higher amide-region NOE intensities up to 54% versus [1H,1H] ES-NOESY and ~50% enhancement for aliphatic resonances, with additional HN-HN contacts absent in the ES experiment.
  • Quantitative comparisons showed average cross-peak intensity increases of ~60% versus presat-NOESY, 89% versus ES, and 30% versus 3919; the highest gain (>200%) was for labile HN resonances that broaden due to water exchange.
  • For RKIP, WADE-NOESY yielded substantially more NOE cross-peaks than ES-NOESY, especially at the two edges of the bandwidth and in the HN-HN region, where some ES cross-peaks were barely detectable.
  • Lowering the WADE pulse amplitude to 3.33 kHz increased intensities of peaks near the water signal relative to ES; WADE-NOESY peaks were negative from −1.0 to 4.7 ppm and positive from 4.7 to 10 ppm due to the W1F90 excitation profile.

Methods

  • NMR experiments were performed on an 850 MHz Bruker Avance NEO equipped with a TCI cryoprobe using uniformly 15N-labeled UbiK48C (0.5 mM) and RKIP (0.3 mM).
  • WADE pulses were implemented into Bruker noesygpph19/noesyesgpph: the third π/2 pulse was replaced by W1F90, and WATERGATE 3919 was replaced by WR4; ten NOESY mixing times were used (25, 50, 75, 100, 150, 200, 300, 400, 500, and 700 ms), with 1024 points in the direct dimension and 256 complex points in the indirect dimension, processed in NMRPipe with a 90°-shifted sine bell and zero-filling to 1024×512.
  • Simulations compared transverse magnetization responses of Grad-3919-Grad, WATERGATE, WATERGATE with flip-back, ES, and WADE schemes over a 20 kHz bandwidth while varying RF offset and amplitude (B1 ±20%).

Limitations

  • Paper-stated: WADE-NOESY peak intensities near the water signal were weaker than corresponding cross-peaks in the [1H,1H] ES-NOESY spectrum, though this can be overcome by increasing water selectivity, i.e., reducing the WADE pulse amplitude.
  • Evident from the text: validation is limited to two well-folded, medium-size proteins (UbiK48C and RKIP) and 2D [1H,1H] NOESY at 850 MHz; 3D heteronuclear NOESY and larger biomacromolecules are anticipated but not demonstrated.
  • Evident from the text: the paper does not include a dedicated limitations section, and comparisons focus on selected cross-peaks/regions and specific Bruker water-suppression schemes, so broader generality across pulse sequences, magnetic fields, and protein classes is not established here.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s10858-022-00407-y

Cites

43 of 44 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 1 Not valid · 17 Not checked · 41 Own results and interpretations

21 more claims

Create a free account to see all 59 claims and to verify the 31 references still open.

See all claims — free account
  • It may state two separate claims as one. 18
  • Probably not a substantial claim. 19
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 43 references

Cited by

See all 12

Metadata

Authors
Manu, V. S., Olivieri, C., & Veglia, G.
Affiliations
University of Minnesota (US)
Corresponding author
Veglia, Gianluigi
Venue
Journal of Biomolecular NMR
Published
2022-12-19
Volume
77
Issue
1-2
Pages
1-14
ISSN
  • 0925-2738 (ISSN-L)
  • 1573-5001
OpenAlex
W4311932963
Cited by
12
References
43
Citations by year
2026: 3 · 2025: 3 · 2024: 5 · 2023: 1
FWCI
0.82
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Biomolecular NMR (publishedVersion)
  • Research Square (submittedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institutes of Health (HL144130)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
  • Physical Sciences › Chemistry › Spectroscopy › Molecular spectroscopy and chirality
Keywords
nuclear Overhauser effect, NOESY, water irradiation, water suppression, high-field NMR, pulse sequence design, RKIP, protein structure determination
MeSH terms
Artificial Intelligence, Proteins, Protons, Water, Nuclear Magnetic Resonance, Biomolecular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Water irradiation devoid pulses enhance the sensitivity of 1H,1H nuclear Overhauser effects. https://app.cochat.ai/papers/10.1007/s10858-022-00407-y
The paper
Manu, V. S., Olivieri, C., & Veglia, G. (2023). Water irradiation devoid pulses enhance the sensitivity of 1H,1H nuclear Overhauser effects. Journal of Biomolecular NMR. https://doi.org/10.1007/s10858-022-00407-y

Data sources