Oscillation Mechanics of the Respiratory System
Abstract
The mechanical impedance of the respiratory system defines the pressure profile required to drive a unit of oscillatory flow into the lungs. Impedance is a function of oscillation frequency, and is measured using the forced oscillation technique. Digital signal processing methods, most notably the Fourier transform, are used to calculate impedance from measured oscillatory pressures and flows. Impedance is a complex function of frequency, having both real and imaginary parts that vary with frequency in ways that can be used empirically to distinguish normal lung function from a variety of different pathologies. The most useful diagnostic information is gained when anatomically based mathematical models are fit to measurements of impedance. The simplest such model consists of a single flow‐resistive conduit connecting to a single elastic compartment. Models of greater complexity may have two or more compartments, and provide more accurate fits to impedance measurements over a variety of different frequency ranges. The model that currently enjoys the widest application in studies of animal models of lung disease consists of a single airway serving an alveolar compartment comprising tissue with a constant‐phase impedance. This model has been shown to fit very accurately to a wide range of impedance data, yet contains only four free parameters, and as such is highly parsimonious. The measurement of impedance in human patients is also now rapidly gaining acceptance, and promises to provide a more comprehensible assessment of lung function than parameters derived from conventional spirometry. © 2011 American Physiological Society.Compr Physiol 1:1233‐1272, 2011.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925
(2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.09.029 · Cited by 2,181
Effects of Obesity on Respiratory Resistance
Zerah, F., Harf, A., Perlemuter, L., Lorino, H., Lorino, A.-M., & Atlan, G. (1993) · Chest · doi:10.1378/chest.103.5.1470 · Cited by 450
Cited by
Technical standards for respiratory oscillometry
King, G. G., Bates, J., Berger, K. I., Calverley, P., de Melo, P. L., Dellacà, R. L., Farré, R., Hall, G. L., Ioan, I., Irvin, C. G., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00753-2019 · Cited by 756
Self-citation
Metadata
- Authors
- Bates, J. H. T., Irvin, C. G., Farré, R., & Hantos, Z.
- Venue
- Comprehensive Physiology
- Publisher
- Wiley
- Published
- 2011-07
- Volume
- 1
- Issue
- 3
- Pages
- 1233-1272
- ISSN
- 2040-4603 (ISSN-L)
- OpenAlex
- W1915139156
- Cited by
- 211
- References
- 3
- Type
- other
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oscillation Mechanics of the Respiratory System. https://app.cochat.ai/papers/10.1002/cphy.c100058
- The paper
- Bates, J. H. T., Irvin, C. G., Farré, R., & Hantos, Z. (2011). Oscillation Mechanics of the Respiratory System. Comprehensive Physiology. https://doi.org/10.1002/cphy.c100058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.