Basic Multicolor Flow Cytometry
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Multicolor flow cytometry is a rapidly evolving technology that uses multiple fluorescent markers to identify and characterize cellular subpopulations of interest, allowing rapid analysis on tens of thousands of cells per second, with the possibility of isolating pure, viable populations by cell sorting for further experimentation. This unit covers the tools needed by the beginning immunologist to plan and run multicolor experiments, with information on fluorochromes and their characteristics, spectral spillover, compensation and spread, instrument and reagent variables, and the basic elements of multicolor panel design. Protocols to quantify and maximize sensitivity by titration of reagents and optimization of instrument settings, as well as basic surface and intracellular cell staining, are included. © 2017 by John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seventeen-colour flow cytometry: unravelling the immune system
Perfetto, S. P., Chattopadhyay, P. K., & Roederer, M. (2004) · Nature Reviews Immunology · doi:10.1038/nri1416 · Cited by 1,019 · cited 2×
“Examples in Figure 5.4.27 show the difference in cutoff and results generated by using an unstained versus an FMO control (Perfetto et al., 2004).”
BackgroundMethodInfluentialSelf-citationInterpreting flow cytometry data: a guide for the perplexed
Herzenberg, L. A., Tung, J., Moore, W. A., Herzenberg, L. A., & Parks, D. R. (2006) · Nature Immunology · doi:10.1038/ni0706-681 · Cited by 464
Considerations for the control of background fluorescence in clinical flow cytometry
Hulspas, R., O'Gorman, M. R. G., Wood, B. L., Gratama, J. W., & Sutherland, D. R. (2009) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.20485 · Cited by 255
Quality assurance for polychromatic flow cytometry using a suite of calibration beads
Perfetto, S. P., Ambrozak, D., Nguyen, R., Chattopadhyay, P. K., & Roederer, M. (2012) · Nature Protocols · doi:10.1038/nprot.2012.126 · Cited by 148
Self-citation
Cited by
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationGuidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Cossarizza, A., Chang, H., Radbruch, A., Abrignani, S., Addo, R., Akdis, M., Andrä, I., Andreata, F., Annunziato, F., Arranz, E., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202170126 · Cited by 531
Monomeric Targeted Protein Degraders
Hanan, E. J., Liang, J., Wang, X., Blake, R. A., Blaquiere, N., & Staben, S. T. (2020) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.0c00093 · Cited by 69
Lucas, F., Gil‐Pulido, J., LaMacchia, J., Preffer, F., Wallace, P. K., & Lopez, P. (2020) · Cytometry Part A · doi:10.1002/cyto.a.23940 · Cited by 10
Metadata
- Authors
- Maciorowski, Z., Chattopadhyay, P. K., & Jain, P.
- Venue
- Current Protocols in Immunology
- Publisher
- Wiley
- Published
- 2017-04
- Volume
- 117
- Issue
- 1
- Pages
- 5.4.1-5.4.38
- ISSN
- 1934-3671 (ISSN-L)
- 1934-368X
- OpenAlex
- W2620284227
- Cited by
- 84
- References
- 4
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Basic Multicolor Flow Cytometry. https://app.cochat.ai/papers/10.1002/cpim.26
- The paper
- Maciorowski, Z., Chattopadhyay, P. K., & Jain, P. (2017). Basic Multicolor Flow Cytometry. Current Protocols in Immunology. https://doi.org/10.1002/cpim.26
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.