CoChat

Telomere length measurement by fluorescence in situ hybridization and flow cytometry: Tips and pitfalls

Open access
Baerlocher, Gabriela M., Mak, Jennifer, Tien, Teri, Lansdorp, Peter M. · 2002 · Cytometry
Cited by 155

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Background: Telomeres containing noncoding DNA repeats at the end of the chromosomes are essential for chromosomal stability and are implicated in regulating the replication and senescence of cells. The gradual loss of telomere repeats in cells has been linked to aging and tumor development and methods to measure telomere length are of increasing interest. At least three methods for measuring the length of telomere repeats have been described: Southern blot analysis and quantitative fluorescence in situ hybridization using either digital fluorescence microscopy (Q‐FISH) or flow cytometry (flow‐FISH). Both Southern blot analysis and Q‐FISH have specific limitations and are time‐consuming, whereas the flow‐FISH technique requires relatively few cells (10 5) and can be completed in a single day. A further advantage of the flow‐FISH method is that data on the telomere length from individual cells and subsets of cells (lymphocytes and granulocytes) can be acquired from the same sample. In order to obtain accurate and reproducible results using the flow‐FISH technique, we systematically explored the influence of various steps in the protocol on telomere length values and established an acceptable range for the most critical parameters. Methods: Isolated leukocytes from whole blood are denatured by heat and 70%/75% formamide, then hybridized with or without a telomere‐specific fluorescein isothiocyante (FITC)‐conjugated peptide nucleic acid probe (PNA). Unbound telomere PNA is washed away, the DNA is counterstained, and telomere fluorescence is measured on a flow cytometer using an argon ion laser (488 nm) to excite FITC. For each sample, duplicates of telomere PNA‐stained and unstained tubes are analyzed. Results: Cell counts and flow‐FISH telomere length measurements were performed on leukocytes and thymocytes of humans and other species. Leukocyte suspensions were prepared by two red blood cell lysis steps with ammonium chloride. Optimal denaturation of DNA was achieved by heating at 85–87°C for 15 min in a solution containing 70%/75% formamide. Hybridization was performed at room temperature with a 0.3 μg/ml telomere‐PNA probe for at least 60–90 min. Unbound telomere‐PNA probe was diluted at least 4,000–40,000 times with wash steps containing 70%/75% formamide at room temperature. LDS 751 and DAPI were suitable as DNA counterstains as they did not show significant interference with telomere length measurement. Conclusions: The use of flow‐FISH for telomere length measurements in nucleated blood cells requires tight adherence to an optimized protocol. The method described here can be used to determine rapidly the telomere length in subsets of nucleated blood cells. Cytometry 47:89–99, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.10053

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 155

Metadata

Authors
Baerlocher, G. M., Mak, J., Tien, T., & Lansdorp, P. M.
Venue
Cytometry
Publisher
Wiley
Published
2002-01-17
Volume
47
Issue
2
Pages
89-99
ISSN
  • 0196-4763 (ISSN-L)
  • 1097-0320
OpenAlex
W2100941174
Cited by
155
References
16
FWCI
8.63
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.