Cell‐by‐cell autofluorescence correction for low signal‐to‐noise systems: Application to epidermal growth factor endocytosis by 3T3 fibroblasts
Open accessThe DOI matches its Crossref record.
Abstract
Autofluorescence of cells can be a major portion of the fluorescence signal in many systems, especially when fluorescent conjugates are used to study receptor‐ligand systems for which there are less than 70,000 receptors per cell. We have devised a method for the cell‐by‐cell correction of autofluorescence for flow cytometric data by using an additional parameter to measure and correct for autofluorescence in the fluorescence channel. The principle has been extended to allow simultaneous correction for autofluorescence and dual‐fluorescence spillover compensation in samples labeled with two different fluorochromes; all corrections were done in software, making them applicable to any flow cytometer. The autofluorescence correction method was used to analyze the acidification of epidermal growth factor (EGF) by Swiss 3T3 cells. EGF is acidified to pH 6.2 starting two min after labeling, with a half‐time for acidification of 45 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
Roederer, M. (2001) · Cytometry · doi:10.1002/1097-0320(20011101)45:3<194::aid-cyto1163>3.0.co;2-c · Cited by 558
Self-citationBillinton, N., & Knight, A. W. (2001) · Analytical Biochemistry · doi:10.1006/abio.2000.5006 · Cited by 499
Considerations for the control of background fluorescence in clinical flow cytometry
Hulspas, R., O'Gorman, M. R. G., Wood, B. L., Gratama, J. W., & Sutherland, D. R. (2009) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.20485 · Cited by 255
Compensation in Flow Cytometry
Roederer, M. (2002) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0114s22 · Cited by 228
“Autofluorescence compensation is more fully described in published references by Roederer and Murphy (1986) and Alberti et al. (1987).”
BackgroundSelf-citationCompensation is not dependent on signal intensity or on number of parameters
Roederer, M. (2001) · Cytometry · doi:10.1002/cyto.10008 · Cited by 20
Self-citation
Metadata
- Authors
- Roederer, M., & Murphy, R. F.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1986-11
- Volume
- 7
- Issue
- 6
- Pages
- 558-565
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2073696750
- Cited by
- 95
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.