Cited by 20Clinical Laboratory Practices and Quality ControlCell Image Analysis TechniquesAdvanced Fluorescence Microscopy Techniques

Compensation is not dependent on signal intensity or on number of parameters

Roederer, Mario·2001·Cytometry

Abstract

A recent paper by Stewart and Stewart on compensation (1) provides useful information and examples of proper and improper compensation. Four-color (and more) analysis is becoming more common, if not routine in many laboratories, with the advent of relatively inexpensive desktop cytometers that collect this many fluorescence signals. As manufacturers extend the technology to perform six or more color experiments easily, the demands on users to understand the complexities of fluorescence compensation become greater. Therefore, I wish to correct a mistake in this manuscript to prevent serious misconceptions about compensation for multicolor applications. The authors observed that multiply-stained cells sometimes appear to be undercompensated, when compensation was properly set based on singly stained compensation controls. Based on this observation, they assert that single-color compensation controls are inadequate for setting proper instrument compensation. Indeed, they provide (in their Appendix) some mathematical modeling to explain why, as more and more colors are added, there appears a pervasive undercompensation in the multiparameter data. In their example, they assert that the fluorescence of a cell that is doubly stained and compensated would be less than the fluorescence of a cell that is singly stained and compensated, going through the mathematics to illustrate this. The first problem is that their model of compensation, even if it were correct, would result in overcompensation, and not the undercompensation the authors are trying to explain. Fundamentally, however, the basic model they use to illustrate how compensation works is incorrect. In their electronic schema, the compensated outputs for each detector are used as the inputs for the compensation for the other detectors. Such a circuit would be unstable, because the values change depending on the order in which they were calculated. In fact, for the single-stained cells example, if the authors were to calculate the detector outputs in the opposite order, they would find that the process yielded proper values! In reality, all inputs to compensation, whether done electronically or by software, are the uncompensated measurements (indeed, this is how the authors performed the calculation for the doubly stained example, in contrast to their singly stained example). When the correct procedure for compensation is performed (whether electronically (2) or by software (3, 4)), the compensated values will always be the same whether or not cells are singly or multiply-stained. This is consistent with our experience that even 11-color data can be properly compensated using singly-stained compensation controls (5). There is no doubt, however, that multicolor data can appear undercompensated even when the compensation is set properly, and that this appearance is exacerbated by the presence of multiple other colors on the same cell. Thus, the question remains as to why such data appear undercompensated, especially when the number of colors used increases (or when the signal intensity increases). As I reported in a manuscript in Cytometry (6), the answer is that this apparent undercompensation is a consequence of photon-counting statistics. The paper explains this in detail, and further demonstrates that we can no longer expect bivariate distributions of multicolor data to be rectilinear, as we have come to expect from our experience with two-color flow cytometry. In conclusion, compensation itself is not dependent on the number of fluorochromes used in an experiment, and neither is it dependent on the signal intensity of any given fluorochrome. Of course, the ability to estimate proper compensation is compromised by using compensation controls that are less bright than experimental stains, whether compensation is performed electronically or by software. Most importantly, the use of singly stained compensation controls are sufficient for properly setting compensation. Mario Roederer*, * Vaccine Research Center, National Institutes of Health, Bethesda, Maryland 20892-3015

Integrity signals

Registry

Crossref · 10.1002/cyto.10008

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Roederer, M.
Affiliations
National Institutes of Health (US)
Corresponding author
Roederer, Mario
Venue
Cytometry
Publisher
Wiley
Published
2001-12-15
Volume
46
Issue
6
Pages
357-357
ISSN
  • 0196-4763 (ISSN-L)
  • 1097-0320
OpenAlex
W2011077460
Cited by
20
References
6
Citations by year
2025: 1 · 2022: 1 · 2021: 1 · 2019: 1 · 2013: 3 · 2012: 2
Type
journal article
Language
en
Open access
closed
Locations
  • Cytometry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
Keywords
multiparameter flow cytometry, undercompensation, compensation control, electronic compensation, software compensation, signal intensity, compensation orders
MeSH terms
Flow Cytometry, Staining and Labeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review