The DOI matches its Crossref record.
Flow cytometric detection of apoptosis: Comparison of the assays of in situ DNA degradation and chromatin changes
Open accessAbstract
The aim of this study was to compare three methods of detection of apoptotic cells: (1) the method based on elution of low molecular weight DNA from the ethanol fixed cells followed by cell staining with DAPI (diamidino‐2–phenylindole) or propidium iodide as the DNA fluorochromes, (2) the method of in situ labeling of DNA strand breaks with biotinylated dUTP, utilizing exogenous terminal deoxyribonucleotide transferase, and (3) the method of analysis of DNA denaturation in situ using acridine orange to differentially stain denatured and doublestranded DNA sections following cell exposure to 0.1 M HCl. Cells of the human promyelocytic HL‐60 line, treated in vitro with the DNA topoisomerase I inhibitor camptothecin, which selectively triggers apoptosis of S‐phase cells, were chosen as a model. The method based on analysis of changes in DNA denaturability was the most sensitive in terms of detection of the earliest changes in chromatin of cells undergoing apoptosis; the increased sensitivity of DNA to denaturation in Sphase cells was measured as early as 100 min after addition of camptothecin. DNA cleavage, assayed either by the univariate measurement of DNA content following extraction of low molecular weight DNA, or by labeling DNA strand breaks with biotinylated dUTP, was detected in S‐phase cells after 120 min incubation with camptothecin. The percentage of apoptotic cells at the late stage of apoptosis, the kinetics of cell transition to apoptosis, and kinetics of the loss of S phase cells were all essentially similar when measured by any method. All three methods can be used to estimate the cell cycle phase specificity of apoptosis, although the method based on DNA strand labeling with biotinylated dUTP by terminal deoxynucleotidyl transferase has the advantage of making it possible to estimate the cell cycle distribution of both the apoptotic and unaffected cell populations. The latter method also appears to be the most specific in terms of detection of apoptosis. © 1994 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cytometry in cell necrobiology: Analysis of apoptosis and accidental cell death (necrosis)
Darzynkiewicz, Z., Juan, G., Li, X., Gorczyca, W., Murakami, T., & Traganos, F. (1997) · Cytometry · doi:10.1002/(sici)1097-0320(19970101)27:1<1::aid-cyto2>3.0.co;2-l · Cited by 1,105
Self-citationPisha, E., Chai, H., Lee, I.-S., Chagwedera, T. E., Farnsworth, N. R., Cordell, G. A., Beecher, C. W. W., Fong, H. H. S., Kinghorn, A. D., Brown, D. M., et al. (1995) · Nature Medicine · doi:10.1038/nm1095-1046 · Cited by 886
Type I Interferons Keep Activated T Cells Alive
Marrack, P., Kappler, J., & Mitchell, T. (1999) · The Journal of Experimental Medicine · doi:10.1084/jem.189.3.521 · Cited by 759
Extramedullary Hematopoiesis Generates Ly-6C high Monocytes That Infiltrate Atherosclerotic Lesions
Robbins, C. S., Chudnovskiy, A., Rauch, P. J., Figueiredo, J.-L., Iwamoto, Y., Gorbatov, R., Etzrodt, M., Weber, G. F., Ueno, T., van Rooijen, N., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.061986 · Cited by 482
Kajstura, M., Halicka, H. D., Pryjma, J., & Darzynkiewicz, Z. (2007) · Cytometry Part A · doi:10.1002/cyto.a.20357 · Cited by 296
Self-citation
Metadata
- Authors
- Hotz, M. A., Gong, J., Traganos, F., & Darzynkiewicz, Z.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1994-03
- Volume
- 15
- Issue
- 3
- Pages
- 237-244
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2046307206
- Cited by
- 228
- References
- 0
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow cytometric detection of apoptosis: Comparison of the assays of in situ DNA degradation and chromatin changes. https://app.cochat.ai/papers/10.1002/cyto.990150309
- The paper
- Hotz, M. A., Gong, J., Traganos, F., & Darzynkiewicz, Z. (1994). Flow cytometric detection of apoptosis: Comparison of the assays of in situ DNA degradation and chromatin changes. Cytometry. https://doi.org/10.1002/cyto.990150309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.