Flow cytometric detection of apoptosis: Comparison of the assays of in situ DNA degradation and chromatin changes

Open access
Hotz, Michel A., Gong, Jianping, Traganos, Frank, Darzynkiewicz, Zbigniew·1994·Cytometry

Abstract

The aim of this study was to compare three methods of detection of apoptotic cells: (1) the method based on elution of low molecular weight DNA from the ethanol fixed cells followed by cell staining with DAPI (diamidino‐2–phenylindole) or propidium iodide as the DNA fluorochromes, (2) the method of in situ labeling of DNA strand breaks with biotinylated dUTP, utilizing exogenous terminal deoxyribonucleotide transferase, and (3) the method of analysis of DNA denaturation in situ using acridine orange to differentially stain denatured and doublestranded DNA sections following cell exposure to 0.1 M HCl. Cells of the human promyelocytic HL‐60 line, treated in vitro with the DNA topoisomerase I inhibitor camptothecin, which selectively triggers apoptosis of S‐phase cells, were chosen as a model. The method based on analysis of changes in DNA denaturability was the most sensitive in terms of detection of the earliest changes in chromatin of cells undergoing apoptosis; the increased sensitivity of DNA to denaturation in Sphase cells was measured as early as 100 min after addition of camptothecin. DNA cleavage, assayed either by the univariate measurement of DNA content following extraction of low molecular weight DNA, or by labeling DNA strand breaks with biotinylated dUTP, was detected in S‐phase cells after 120 min incubation with camptothecin. The percentage of apoptotic cells at the late stage of apoptosis, the kinetics of cell transition to apoptosis, and kinetics of the loss of S phase cells were all essentially similar when measured by any method. All three methods can be used to estimate the cell cycle phase specificity of apoptosis, although the method based on DNA strand labeling with biotinylated dUTP by terminal deoxynucleotidyl transferase has the advantage of making it possible to estimate the cell cycle distribution of both the apoptotic and unaffected cell populations. The latter method also appears to be the most specific in terms of detection of apoptosis. © 1994 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.990150309

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Hotz, M. A., Gong, J., Traganos, F., & Darzynkiewicz, Z.
Venue
Cytometry
Publisher
Wiley
Published
1994-03
Volume
15
Issue
3
Pages
237-244
ISSN
  • 0196-4763 (ISSN-L)
  • 1097-0320
OpenAlex
W2046307206
Cited by
228
References
0
FWCI
6.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flow cytometric detection of apoptosis: Comparison of the assays of in situ DNA degradation and chromatin changes. https://app.cochat.ai/papers/10.1002/cyto.990150309
The paper
Hotz, M. A., Gong, J., Traganos, F., & Darzynkiewicz, Z. (1994). Flow cytometric detection of apoptosis: Comparison of the assays of in situ DNA degradation and chromatin changes. Cytometry. https://doi.org/10.1002/cyto.990150309

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.