Improved sensitivity in flow cytometric intracellular ionized calcium measurement using fluo‐3/Fura Red fluorescence ratios
Open accessThe DOI matches its Crossref record.
Abstract
Measurment of changes in intracellular ionized calcium concentrations ([Ca 2+]i) has proved to be of wide use in the study of cellular responses to activating stimuli. The fluorescent dye Indo‐1 has successfully been used in flow cytometry for this purpose, and when used as a ratiometric indicator it provides optimum sensitivity and accuracy. Unfortunately, this dye requires ultraviolet (UV) excitation which is often not available. We show here that similar results can be obtained using a ratio of green to red fluorescence from the simultaneous loading of the dyes Fura Red and fluo‐3. Both Fura Red and fluo‐3 are excited using the commonly available blue 488 nm laser line. With appropriate concentrations of the two dyes, the magnitude of response with the fluo‐3/Fura Red ratio is greater than that achieved with indo‐1, while the intercellular variation in measurement is similar to that seen with indo‐1. Analyses can be simultaneously combined with immunofluorescent detection of PE‐labeled antibodies to enable [Ca 2+]i measurement within cell subsets. © 1994 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flavonoids Protect Neuronal Cells from Oxidative Stress by Three Distinct Mechanisms
Ishige, K., Schubert, D., & Sagara, Y. (2001) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(00)00498-6 · Cited by 841
Flow cytometry of apoptotic cell death
Vermes, I., Haanen, C., & Reutelingsperger, C. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00233-7 · Cited by 789
Measurement of Intracellular Calcium
Takahashi, A., Camacho, P., Lechleiter, J. D., & Herman, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1089 · Cited by 763
Hemagglutinin-stem nanoparticles generate heterosubtypic influenza protection
Yassine, H. M., Boyington, J. C., McTamney, P. M., Wei, C.-J., Kanekiyo, M., Kong, W.-P., Gallagher, J. R., Wang, L., Zhang, Y., Joyce, M. G., et al. (2015) · Nature Medicine · doi:10.1038/nm.3927 · Cited by 699
Kerkmann, M., Rothenfusser, S., Hornung, V., Towarowski, A., Wagner, M., Sarris, A., Giese, T., Endres, S., & Hartmann, G. (2003) · The Journal of Immunology · doi:10.4049/jimmunol.170.9.4465 · Cited by 352
Metadata
- Authors
- Novak, E. J., & Rabinovitch, P. S.
- Venue
- Cytometry
- Publisher
- Wiley
- Published
- 1994-10
- Volume
- 17
- Issue
- 2
- Pages
- 135-141
- ISSN
- 0196-4763 (ISSN-L)
- 1097-0320
- OpenAlex
- W2070726483
- Cited by
- 132
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved sensitivity in flow cytometric intracellular ionized calcium measurement using fluo‐3/Fura Red fluorescence ratios. https://app.cochat.ai/papers/10.1002/cyto.990170205
- The paper
- Novak, E. J., & Rabinovitch, P. S. (1994). Improved sensitivity in flow cytometric intracellular ionized calcium measurement using fluo‐3/Fura Red fluorescence ratios. Cytometry. https://doi.org/10.1002/cyto.990170205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.