The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Intracellular phospho‐protein staining techniques for flow cytometry: Monitoring single cell signaling events
Open accessAbstract
Background: Recent advances in intracellular staining techniques, cytometer technology, fluorescent reagents, and antibody production have expanded the number of intracellular antigens that can be analyzed by flow cytometry. Measurement of protein phosphorylation with phospho‐specific antibodies has given insight into kinase signaling cascades. However, available techniques for phospho‐epitope staining can differ greatly, making it necessary to understand the differences between the outcomes when such techniques are applied and to develop robust and reproducible methods of application. Methods: Ten different cellular fixation and permeabilization techniques were tested for their ability to provide phospho‐specific staining. Combinations of formaldehyde, methanol, ethanol, acetone, Triton X‐100, and saponin were used as fixation and permeabilization reagents. Phospho‐specific antibodies were labeled with Alexa Fluor dyes to provide multicolor analysis of different signaling events simultaneously within individual cells. Results: Fixing cells with 1.5% formaldehyde followed by permeabilization in methanol gave optimal results for pERK, pp38, pJNK, pStat1, pStat5, and pStat6 staining. Alteration of formaldehyde fixation and methanol permeabilization times affected measurements of phosphorylation induction. Phospho‐specific flow cytometric analyses correlated well with Western blotting, providing cross platform validation of the technique. Conclusions: Measuring phosphorylation events by flow cytometry provides a rapid and efficient way to measure kinase cascades in individual cells. Stability of phospho‐epitopes in methanol allows long‐term storage of samples prior to analysis. Multiple signaling cascades can be monitored simultaneously through the use of different fluorophore labels to determine specificity of ligands or inhibitors. Application of optimized techniques to heterogeneous cell types such as peripheral blood or murine splenocytes may allow signaling to be analyzed simultaneously in immune cell subsets. Cytometry Part A 55A:61–70, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitogen-Activated Protein Kinase Pathways Mediated by ERK, JNK, and p38 Protein Kinases
Johnson, G. L., & Lapadat, R. (2002) · Science · doi:10.1126/science.1072682 · Cited by 4,295
A Road Map for Those Who Don't Know JAK-STAT
Aaronson, D. S., & Horvath, C. M. (2002) · Science · doi:10.1126/science.1071545 · Cited by 1,337
Signaling through the JAK/STAT pathway, recent advances and future challenges
Kisseleva, T., Bhattacharya, S., Braunstein, J., & Schindler, C. W. (2002) · Gene · doi:10.1016/s0378-1119(02)00398-0 · Cited by 1,154
The Biochemical Basis of an All-or-None Cell Fate Switch in Xenopus Oocytes
Ferrell, J. E., & Machleder, E. M. (1998) · Science · doi:10.1126/science.280.5365.895 · Cited by 1,052
Krutzik, P. O., Irish, J. M., Nolan, G. P., & Perez, O. D. (2004) · Clinical Immunology · doi:10.1016/j.clim.2003.11.009 · Cited by 335
Self-citationFiering, S., Northrop, J. P., Nolan, G. P., Mattila, P. S., Crabtree, G. R., & Herzenberg, L. A. (1990) · Genes & Development · doi:10.1101/gad.4.10.1823 · Cited by 294
Self-citationSimultaneous measurement of multiple active kinase states using polychromatic flow cytometry
Perez, O. D., & Nolan, G. P. (2002) · Nature Biotechnology · doi:10.1038/nbt0202-155 · Cited by 279
Self-citationBistability in the JNK cascade
Bagowski, C. P., & Ferrell, J. E. (2001) · Current Biology · doi:10.1016/s0960-9822(01)00330-x · Cited by 237
Chow, S., Patel, H., & Hedley, D. W. (2001) · Cytometry · doi:10.1002/cyto.1067 · Cited by 181
Detection of Intracellular Phosphorylated STAT-1 by Flow Cytometry
Fleisher, T. A., Dorman, S. E., Anderson, J. A., Vail, M., Brown, M. R., & Holland, S. M. (1999) · Clinical Immunology · doi:10.1006/clim.1998.4654 · Cited by 132
Activation of the PKB/AKT Pathway by ICAM-2
Perez, O. D., Kinoshita, S. M., Hitoshi, Y., Payan, D. G., Kitamura, T., Nolan, G. P., & Lorens, J. B. (2002) · Immunity · doi:10.1016/s1074-7613(02)00266-2 · Cited by 125
Self-citationDetection of Intracellular Phosphorylated STAT-4 by Flow Cytometry
Uzel, G., Frucht, D. M., Fleisher, T. A., & Holland, S. M. (2001) · Clinical Immunology · doi:10.1006/clim.2001.5078 · Cited by 98
Maródi, L., Goda, K., Palicz, A., & Szabó, G. (2001) · Clinical and Experimental Immunology · doi:10.1046/j.1365-2249.2001.01693.x · Cited by 89
Single-cell analysis of signal transduction in CD4 T cells stimulated by antigen in vivo
Zell, T., Khoruts, A., Ingulli, E. G., Bonnevier, J. L., Mueller, D. L., & Jenkins, M. K. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191567898 · Cited by 75
Kao, C., Wu, M.-C., Chiu, Y., Lin, J.-L., Wu, Y.-C., Yueh, Y.-Y., Chen, L., Shaio, M., & King, C. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.10.3672-3677.2001 · Cited by 44
Flow cytometric detection of total and serine 473 phosphorylated Akt
Tazzari, P. L., Cappellini, A., Bortul, R., Ricci, F., Billi, A. M., Tabellini, G., Conte, R., & Martelli, A. M. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10262 · Cited by 30
Ruitenberg, J. J., & Waters, C. A. (2003) · Journal of Immunological Methods · doi:10.1016/s0022-1759(02)00507-0 · Cited by 24
Dorn, I. (2002) · Immunobiology · doi:10.1078/0171-2985-00203 · Cited by 12
Palmblad, K., & Andersson, U. (2000) · Biotechnic & Histochemistry · doi:10.3109/10520290009066487 · Cited by 11
Cited by
Bendall, S. C., Simonds, E. F., Qiu, P., Amir, E.-A. D., Krutzik, P. O., Finck, R., Bruggner, R. V., Melamed, R., Trejo, A., Ornatsky, O. I., et al. (2011) · Science · doi:10.1126/science.1198704 · Cited by 2,279
Self-citationmiR-181a Is an Intrinsic Modulator of T Cell Sensitivity and Selection
Li, Q.-J., Chau, J., Ebert, P. J. R., Sylvester, G., Min, H., Liu, G., Braich, R., Manoharan, M., Soutschek, J., Skare, P., et al. (2007) · Cell · doi:10.1016/j.cell.2007.03.008 · Cited by 1,157
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Single Cell Profiling of Potentiated Phospho-Protein Networks in Cancer Cells
Irish, J. M., Hovland, R., Krutzik, P. O., Perez, O. D., Bruserud, Ø., Gjertsen, B. T., & Nolan, G. P. (2004) · Cell · doi:10.1016/j.cell.2004.06.028 · Cited by 684
Self-citationPonader, S., Chen, S.-S., Buggy, J. J., Balakrishnan, K., Gandhi, V., Wierda, W. G., Keating, M. J., O'Brien, S., Chiorazzi, N., & Burger, J. A. (2012) · Blood · doi:10.1182/blood-2011-10-386417 · Cited by 640
Metadata
- Authors
- Krutzik, P. O., & Nolan, G. P.
- Venue
- Cytometry Part A
- Publisher
- Wiley
- Published
- 2003-09-17
- Volume
- 55A
- Issue
- 2
- Pages
- 61-70
- ISSN
- 1552-4922 (ISSN-L)
- 1552-4930
- OpenAlex
- W2091824579
- Cited by
- 562
- References
- 19
- FWCI
- 10.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.