Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Accurate and simple discrimination of mouse pulmonary dendritic cell and macrophage populations by flow cytometry: Methodology and new insights

Open access
Vermaelen, Karim, Pauwels, Romain · 2004 · Cytometry Part A

Abstract

Background: The need to accurately discriminate dendritic cells (DCs) and macrophages (Mphs) in mouse lungs is critical given important biological differences. However, a validated flow cytometry–based method is still lacking, resulting in much confusion between both cell types. Methods: Single‐cell suspensions freshly obtained from collagenase‐digested lung tissue were stained with a CD11c‐specific monoclonal antibody, detected using a PE‐Cy5 or APC‐conjugated secondary reagent. Cellular immunophenotype was simultaneously explored using a panel of PE‐conjugated markers. The FL1 or FITC‐detection channel was reserved for the assessment of autofluorescence. Results: CD11c‐bright cells were heterogeneous and displayed a bimodal distribution with regard to autofluorescence (AF). CD11c+/low‐AF cells were lineage‐negative and showed features compatible with myeloid DCs. This was confirmed by morphology, potent T‐cell stimulatory function in a mixed‐leukocyte reaction, surface expression of MHCII and costimulatory molecules, and further immunophenotypical criteria, including the expression of Mac‐1 and absence of CD8α. In contrast, CD11c+/high‐AF cells displayed the features of pulmonary Mphs, including typical Mph morphology, very weak induction of T‐cell proliferation, low to absent expression of MHCII and costimulatory molecules, and very low levels of Mac‐1 as well as F4/80. We also show that only CD11c+/high‐AF cells strongly expressed the macrophage marker MOMA‐2, while interestingly Mac‐3 was expressed at high levels by CD11c+/high‐AF and low‐AF alike. Conclusions: This study shows that the combination of CD11c‐expression and autofluorescence is necessary and sufficient to accurately separate DCs from macrophage subpopulations in mouse lungs. © 2004 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.a.20064

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 243

Metadata

Authors
Vermaelen, K., & Pauwels, R.
Venue
Cytometry Part A
Publisher
Wiley
Published
2004-08-26
Volume
61A
Issue
2
Pages
170-177
ISSN
  • 1552-4922 (ISSN-L)
  • 1552-4930
OpenAlex
W2080911945
Cited by
243
References
1
FWCI
4.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accurate and simple discrimination of mouse pulmonary dendritic cell and macrophage populations by flow cytometry: Methodology and new insights. https://app.cochat.ai/papers/10.1002/cyto.a.20064
The paper
Vermaelen, K., & Pauwels, R. (2004). Accurate and simple discrimination of mouse pulmonary dendritic cell and macrophage populations by flow cytometry: Methodology and new insights. Cytometry Part A. https://doi.org/10.1002/cyto.a.20064

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.