Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record.

Selecting fluorochrome conjugates for maximum sensitivity

Maecker, Holden T., Frey, Tom, Nomura, Laurel E., Trotter, Joe·2004·Cytometry Part A

Abstract

Most users of flow cytometry are aware that, to maximize sensitivity for an antibody whose staining is dim, a bright fluorochrome such as phycoerythrin (PE) should be selected for that conjugate. What is often less well appreciated is the role that spectral overlap plays in determining the sensitivity of a given fluorescence channel. This has become more of an issue with the advent of polychromatic flow cytometry (up to 12 colors) (1) and with the introduction of digital electronics and postacquisition compensation, which can affect resolution, as described below. In this article, the pitfalls of selecting suboptimal conjugate combinations are highlighted, in addition to general rules that should guide conjugate selection. We start from first principles to describe how spectral overlap contributes to the observed background in a given fluorescence channel. What this implies for flow cytometry is that brightly fluorescent populations tend to have greater standard deviation (S.D.) than dimly fluorescent populations (once the population is well above electronic noise). The use of a logarithmic scale visually compensates for this tendency by compressing the data at the high end of the fluorescence scale. Thus, populations tend to keep a similar shape on a log scale, whether they are bright or dim, although the bright populations have much greater S.D. It is also for this reason that the coefficient of variation rather than S.D. is commonly used as a measure of dispersion of a flow cytometric population. Because the coefficient of variation is adjusted for the population mean, it tends to be similar for bright and dim fluorescent populations. As we all know, cells stained with an antibody labeled with fluorescein isothiocyanate (FITC) will fluoresce primarily in the FITC channel and secondarily in the PE channel. This is due to the spectral overlap of the dyes and the resultant spillover of FITC signal into the PE detector. Thus, when a FITC conjugate is very bright, it has a large S.D. not only in the FITC channel but also in the PE channel. We "compensate" for the spectral overlap of FITC into PE by measuring spillover and applying a correction to the PE signal for each data point such that a FITC-stained population, on average, shows no PE fluorescence after compensation (Fig. 1). The greater the spillover of FITC into PE, the higher the compensation required, and the higher the measured S.D. of that population in the PE channel. One way to think of this is that by compensating we are moving a population from an area of the display where the S.D. is relatively large into an area where the S.D. is expected to be relatively small. However, the compensated population's S.D. remains relatively large, so we are left with "data spread," which refers to the fact that bright fluorescent signals tend to spread in the dimensions against which they are compensated. Compensation of a FITC-positive population in the PE channel. Left: The FITC-positive (black) population also fluoresces in the PE channel. Right: After compensation, the mean of the FITC-positive (black) and FITC-negative (grey) populations have been aligned. However, the positive population has a greater variance in the PE dimension than does the negative population due to "data spread." Because of data spread of a FITC-positive population after compensation against PE, it will occupy more space in the PE dimension than will a FITC-negative population (Fig. 1). In general, the greater the spillover, the greater the spread of the compensated positive population. Because bright fluorescent populations have higher variance than dim ones, they will exhibit more data spread. This in turn affects the resolution of dim signals in the second channel (e.g., PE). Simply stated, you will not be able to resolve very dim events above background in the PE channel when those events also have a very bright signal in the FITC channel. In antigen-specific cytokine flow cytometry, high sensitivity is required to detect potentially rare populations of cytokine-positive cells. Many users select PE or allophycocyanin (APC) conjugates for their anti-cytokine antibodies because of the relatively high intensity of these fluorochromes. However, the following example demonstrates that this may not always produce the desired result. When a relatively bright antibody (to CD8) is used in the APC-Cy7 channel, the resulting data spread in the APC channel can mask the ability to detect dim interferon-γ (IFNγ) APC-positive cells (Fig. 2A). The same is true of the PE channel, where CD4 PE-Cy7-positive cells cause data spread that makes detecting dim IL-2 PE-positive events difficult. Note that the data spread is restricted to populations positive for APC-Cy7 or PE-Cy7, respectively. For example, the CD8 APC-Cy7-positive cells, negative for CD4 PE-Cy7, have a much tighter distribution in the PE channel than does the CD4 PE-Cy7-positive population. To demonstrate that this data spread is depen

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.a.20092

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
Maecker, H. T., Frey, T., Nomura, L. E., & Trotter, J.
Venue
Cytometry Part A
Publisher
Wiley
Published
2004-11-09
Volume
62A
Issue
2
Pages
169-173
ISSN
  • 1552-4922 (ISSN-L)
  • 1552-4930
OpenAlex
W2046682570
Cited by
216
References
0
FWCI
1.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selecting fluorochrome conjugates for maximum sensitivity. https://app.cochat.ai/papers/10.1002/cyto.a.20092
The paper
Maecker, H. T., Frey, T., Nomura, L. E., & Trotter, J. (2004). Selecting fluorochrome conjugates for maximum sensitivity. Cytometry Part A. https://doi.org/10.1002/cyto.a.20092

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.