The DOI matches its Crossref record.
Novel fluorescence assay using calcein‐AM for the determination of human erythrocyte viability and aging
Abstract
Background: A highly sensitive, fast, and simple flow cytometric assay to assess human red blood cell (RBCs) viability and aging is reported. Methods: The assay described in this report is based on the use of acetoxymethyl ester of calcein (calcein‐AM), a fluorescein derivative and nonfluorescent vital dye that passively crosses the cell membrane of viable cells and is converted by cytosolic esterases into green fluorescent calcein, which is retained by cells with intact membranes and inactive multidrug resistance protein. The loss of calcein can be easily determined by flow cytometry, and the cytosolic localization of esterases was demonstrated by spectrofluorometric analyses. Results: We found that RBCs incubated with Ca 2+, which induces a rapid and modulated self‐death that shares several features with apoptosis (Bratosin et al., Cell Death Differ 2001;8:1143–1156), externalized phosphatidylserine and lost calcein staining and cytosolic adenosine triphosphate content. Double labeling using phycoerythrin‐labeled annexin‐V and calcein‐AM showed that the decrease of esterase activity is an early event that precedes the externalization of phosphatidylserine residues. In addition, this assay allowed us to distinguish young and aged RBCs isolated by ultracentrifugation in a self‐forming Percoll gradient and can be considered as a reliable marker of RBC aging. Conclusions: Calcein‐AM assay may represent a wide application for assessing RBC viability, particularly in blood banks. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell Proliferation and Cytotoxicity Assays
Adan, A., Kiraz, Y., & Baran, Y. (2016) · Current Pharmaceutical Biotechnology · doi:10.2174/1389201017666160808160513 · Cited by 584
A cell nanoinjector based on carbon nanotubes
Chen, X., Kis, A., Zettl, A., & Bertozzi, C. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700567104 · Cited by 377
Antioxidative and prooxidative effects of quercetin on A549 cells
Robaszkiewicz, A., Balcerczyk, A., & Bartosz, G. (2007) · Cell Biology International · doi:10.1016/j.cellbi.2007.04.009 · Cited by 279
Sorting drops and cells with acoustics: acoustic microfluidic fluorescence-activated cell sorter
Schmid, L., Weitz, D. A., & Franke, T. (2014) · Lab Chip · doi:10.1039/c4lc00588k · Cited by 271
Pre-analytical and analytical issues in the analysis of blood microparticles
Yuana, Y., Bertina, R., & Osanto, S. (2011) · Thrombosis and Haemostasis · doi:10.1160/th10-09-0595 · Cited by 268
Metadata
- Authors
- Bratosin, D., Mitrofan, L., Palii, C., Estaquier, J., & Montreuil, J.
- Venue
- Cytometry Part A
- Publisher
- Wiley
- Published
- 2005-05-24
- Volume
- 66A
- Issue
- 1
- Pages
- 78-84
- ISSN
- 1552-4922 (ISSN-L)
- 1552-4930
- OpenAlex
- W2089022942
- Cited by
- 237
- References
- 0
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel fluorescence assay using calcein‐AM for the determination of human erythrocyte viability and aging. https://app.cochat.ai/papers/10.1002/cyto.a.20152
- The paper
- Bratosin, D., Mitrofan, L., Palii, C., Estaquier, J., & Montreuil, J. (2005). Novel fluorescence assay using calcein‐AM for the determination of human erythrocyte viability and aging. Cytometry Part A. https://doi.org/10.1002/cyto.a.20152
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.