CoChat

Single Cell Analysis of Human Tissues and Solid Tumors with Mass Cytometry

Leelatian, Nalin, Doxie, Deon B., Greenplate, Allison R., Mobley, Bret C., Lehman, Jonathan M., Sinnaeve, Justine, Kauffman, Rondi M., Werkhaven, Jay A., Mistry, Akshitkumar M., Weaver, Kyle D., Thompson, Reid C., Massion, Pierre P., Hooks, Mary A., Kelley, Mark C., Chambless, Lola B., Ihrie, Rebecca A., Irish, Jonathan M. · 2017 · Cytometry Part B: Clinical Cytometry
Cited by 77

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: Mass cytometry measures 36 or more markers per cell and is an appealing platform for comprehensive phenotyping of cells in human tissue and tumor biopsies. While tissue disaggregation and fluorescence cytometry protocols were pioneered decades ago, it is not known whether established protocols will be effective for mass cytometry and maintain cancer and stromal cell diversity. Methods: Tissue preparation techniques were systematically compared for gliomas and melanomas, patient derived xenografts of small cell lung cancer, and tonsil tissue as a control. Enzymes assessed included DNase, HyQTase, TrypLE, collagenase (Col) II, Col IV, Col V, and Col XI. Fluorescence and mass cytometry were used to track cell subset abundance following different enzyme combinations and treatment times. Results: Mechanical disaggregation paired with enzymatic dissociation by Col II, Col IV, Col V, or Col XI plus DNase for 1 hour produced the highest yield of viable cells per gram of tissue. Longer dissociation times led to increasing cell death and disproportionate loss of cell subsets. Key markers for establishing cell identity included CD45, CD3, CD4, CD8, CD19, CD64, HLA-DR, CD11c, CD56, CD44, GFAP, S100B, SOX2, nestin, vimentin, cytokeratin, and CD31. Mass and fluorescence cytometry identified comparable frequencies of cancer cell subsets, leukocytes, and endothelial cells in glioma (R = 0.97), and tonsil (R = 0.98). Conclusions: This investigation establishes standard procedures for preparing viable single cell suspensions that preserve the cellular diversity of human tissue microenvironments. This article is protected by copyright. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.b.21542

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 77

Metadata

Authors
Leelatian, N., Doxie, D. B., Greenplate, A. R., Mobley, B. C., Lehman, J. M., Sinnaeve, J., Kauffman, R. M., Werkhaven, J. A., Mistry, A. M., Weaver, K. D., Thompson, R. C., Massion, P. P., Hooks, M. A., Kelley, M. C., Chambless, L. B., Ihrie, R. A., & Irish, J. M.
Venue
Cytometry Part B: Clinical Cytometry
Publisher
Wiley
Published
2017-07-18
ISSN
1552-4949 (ISSN-L)
OpenAlex
W2514434849
Cited by
77
References
5
FWCI
4.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single Cell Analysis of Human Tissues and Solid Tumors with Mass Cytometry. https://app.cochat.ai/papers/10.1002/cyto.b.21542
The paper
Leelatian, N., Doxie, D. B., Greenplate, A. R., Mobley, B. C., Lehman, J. M., Sinnaeve, J., Kauffman, R. M., Werkhaven, J. A., Mistry, A. M., Weaver, K. D., Thompson, R. C., Massion, P. P., Hooks, M. A., Kelley, M. C., Chambless, L. B., Ihrie, R. A., & Irish, J. M. (2017). Single Cell Analysis of Human Tissues and Solid Tumors with Mass Cytometry. Cytometry Part B: Clinical Cytometry. https://doi.org/10.1002/cyto.b.21542

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.