Cited by 6

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Possible alternative strategies to implement basophil activation testing in multicentric studies

Bourgoin, Pénélope, Dupont, Thomas, Agabriel, Chantal, Carsin, Ania, Verles, Aurélie, Cabanski, Maciej, Vitaliti, Alessandra, Busnel, Jean‐Marc·2024·Cytometry Part B: Clinical Cytometry

Abstract

The Basophil Activation Test (BAT) enables flow cytometry characterization of basophil reactivity against specific allergenic molecules. The focus now revolves around democratizing this tool, but, as blood sample stability could be challenging, after having developed a simplified approach, herein, we aimed to characterize two strategies for implementing BAT in multicentric studies: store and ship blood before or after sample processing. Fresh heparin‐ and EDTA‐anticoagulated whole blood samples followed both BAT workflows: “collect, store, process & analyze” or “collect, process, store & analyze”. Storage temperatures of 18–25 °C or 2–8 °C and preservation times from 0 to 7 days were considered. Interleukin‐3 was also evaluated. With the “collect, store, process & analyze” workflow, heparin‐anticoagulated blood and 18–25 °C storage were better than other conditions. While remaining possible, basophil activation exhibited a possible reactivity decay after 24 h. Under the conditions tested, interleukin‐3 had no role in enhancing basophil reactivity after storage. Conversely, the “collect, process, store & analyze” workflow demonstrated that either heparin‐ or EDTA‐anticoagulated blood can be processed and kept up to 7 days at 18–25 °C or 2–8 °C before being analyzed. Various strategies can be implemented to integrate BAT in multicentric studies. The “collect, store, process & analyze” workflow remains a simplified logistical approach, but depending on time required to ship from the clinical centers to the reference laboratories, it might not be applicable, or should be used with caution. The “collect, process, store & analyze” workflow may constitute a workflow improvement to provide significant flexibility without impact on basophil reactivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/cyto.b.22172

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 32

  1. 10.1111/all.14752 · DOI
  2. 10.1016/j.waojou.2019.100080 · DOI · Paper page
  3. 10.1016/j.jim.2020.112793 · DOI
  4. 10.1016/j.jaci.2010.10.007 · DOI
  5. 10.1080/14737159.2020.1782192 · DOI
  6. 10.3390/ijms23094979 · DOI
  7. 10.1111/all.15610 · DOI
  8. 10.1002/cyto.b.20570 · DOI
  9. 10.1111/ijlh.12753 · DOI
  10. 10.1016/j.waojou.2019.100043 · DOI
  11. 10.1002/cyto.a.23078 · DOI
  12. 10.1002/cyto.b.20419 · DOI
  13. 10.1016/j.jim.2011.09.003 · DOI
  14. 10.1002/cyto.b.21868 · DOI
  15. 10.1111/j.1398-9995.2006.01039.x · DOI
  16. 10.1016/j.jaci.2011.07.021 · DOI
  17. 10.1002/cyto.b.21251 · DOI
  18. 10.1007/s11882-018-0831-5 · DOI
  19. 10.1111/all.12698 · DOI
  20. 10.1016/j.jaip.2021.04.045 · DOI
  21. 10.1111/all.15797 · DOI
  22. Litwin V., 2019, Validation of assays performed by flow cytometry
  23. 10.1016/j.jaci.2016.04.060 · DOI
  24. 10.3389/fimmu.2020.602660 · DOI
  25. 10.1002/cyto.b.21622 · DOI
  26. 10.1002/cyto.a.23570 · DOI
  27. 10.1111/ijlh.12678 · DOI
  28. Santos A. Alpan O. &Hoffmann H. J.(2020).Basophil activation test: mechanisms and considerations for use in clinical trials and clinical practice.https://doi.org/10.22541/au.159493194.42634850 · DOI
  29. 10.1016/j.jaci.2014.09.001 · DOI
  30. 10.1186/s13601-016-0098-7 · DOI
  31. 10.4049/jimmunol.0801782 · DOI
  32. 10.1111/j.1398-9995.2009.02004.x · DOI

Cited by

Sorted by citations

See all 6

Metadata

Authors
Bourgoin, P., Dupont, T., Agabriel, C., Carsin, A., Verles, A., Cabanski, M., Vitaliti, A., & Busnel, J.
Affiliations
  • Global Research Organization Beckman Coulter Life Sciences Marseille France
  • Department of Pediatric Emergency Medicine Timone University Hospital, APHM Marseille France
  • Department of Pediatric Emergency Medicine Saint Joseph Hospital Marseille France
  • BioMarker Development Novartis Institutes for Biomedical Research Basel Switzerland
Venue
Cytometry Part B: Clinical Cytometry
Publisher
Wiley
Published
2024-04-04
Volume
106
Issue
5
Pages
392-404
ISSN
  • 1552-4949
  • 1552-4957
Cited by
6
References
3
Language
en
Funders
Beckman Coulter Foundation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Possible alternative strategies to implement basophil activation testing in multicentric studies. https://app.cochat.ai/papers/10.1002/cyto.b.22172
The paper
Bourgoin, P., Dupont, T., Agabriel, C., Carsin, A., Verles, A., Cabanski, M., Vitaliti, A., & Busnel, J. (2024). Possible alternative strategies to implement basophil activation testing in multicentric studies. Cytometry Part B: Clinical Cytometry. https://doi.org/10.1002/cyto.b.22172