Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 305

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Engineering and characterization of the long‐acting glucagon‐like peptide‐1 analogue LY2189265, an Fc fusion protein

Glaesner, Wolfgang, Mark Vick, Andrew, Millican, Rohn, Ellis, Bernice, Tschang, Sheng‐Hung, Tian, Yu, Bokvist, Krister, Brenner, Martin, Koester, Anja, Porksen, Niels, Etgen, Garret, Bumol, Tom·2010·Diabetes/Metabolism Research and Reviews

Abstract

Background: Glucagon‐like peptide‐1 (GLP‐1) receptor agonists are novel agents for type 2 diabetes treatment, offering glucose‐dependent insulinotropic effects, reduced glucagonemia and a neutral bodyweight or weight‐reducing profile. However, a short half‐life (minutes), secondary to rapid inactivation by dipeptidyl peptidase‐IV (DPP‐IV) and excretion, limits the therapeutic potential of the native GLP‐1 hormone. Recently, the GLP‐1 receptor agonist exenatide injected subcutaneously twice daily established a novel therapy class. Developing long‐acting and efficacious GLP‐1 analogues represents a pivotal research goal. We developed a GLP‐1 immunoglobulin G (IgG4) Fc fusion protein (LY2189265) with extended pharmacokinetics and activity. Methods: In vitro and in vivo activity of LY2189265 was characterized in rodent and primate cell systems and animal models. Results: LY2189265 retained full receptor activity in vitro and elicited insulinotropic activity in islets similar to native peptide. Half‐life in rats and cynomolgus monkeys was 1.5–2 days, and serum immunoreactivity representing active compound persisted > 6 days. In rats, LY2189265 enhanced insulin responses during graded glucose infusion 24 h after one dose. LY2189265 increased glucose tolerance in diabetic mice after one dose and lowered weight and delayed hyperglycaemia when administered twice weekly for 4 weeks. In monkeys, LY2189265 significantly increased glucose‐dependent insulin secretion for up to a week after one dose, retained efficacy when administered subchronically (once weekly for 4 weeks) and was well tolerated. Conclusions: LY2189265 retains the effects of GLP‐1 with increased half‐life and efficacy, supporting further evaluation as a once‐weekly treatment of type 2 diabetes. Copyright © 2010 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/dmrr.1080

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 305

Metadata

Authors
Glaesner, W., Mark Vick, A., Millican, R., Ellis, B., Tschang, S., Tian, Y., Bokvist, K., Brenner, M., Koester, A., Porksen, N., Etgen, G., & Bumol, T.
Venue
Diabetes/Metabolism Research and Reviews
Publisher
Wiley
Published
2010-05
Volume
26
Issue
4
Pages
287-296
ISSN
  • 1520-7552 (ISSN-L)
  • 1520-7560
OpenAlex
W1972057139
Cited by
305
References
23
FWCI
5.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.