CoChat

Development and validation of an ultra‐fast and sensitive microflow liquid chromatography‐tandem mass spectrometry (MFLC‐MS/MS) method for quantification of LSD and its metabolites in plasma and application to a controlled LSD administration study in humans

Steuer, Andrea E., Poetzsch, Michael, Stock, Lorena, Eisenbeiss, Lisa, Schmid, Yasmin, Liechti, Matthias E., Kraemer, Thomas · 2017 · Drug Testing and Analysis
Cited by 41

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Lysergic acid diethylamide (LSD) is a semi‐synthetic hallucinogen that has gained popularity as a recreational drug and has been investigated as an adjunct to psychotherapy. Analysis of LSD represents a major challenge in forensic toxicology due to its instability, low drug concentrations, and short detection windows in biological samples. A new, fast, and sensitive microflow liquid chromatography (MFLC) tandem mass spectrometry method for the validated quantification of LSD, iso‐LSD, 2‐oxo 3‐hydroxy‐LSD (oxo‐HO‐LSD), and N‐desmethyl‐LSD (nor‐LSD) was developed in plasma and applied to a controlled pharmacokinetic (PK) study in humans to test whether LSD metabolites would offer for longer detection windows. Five hundred microlitres of plasma were extracted by solid phase extraction. Analysis was performed on a Sciex Eksigent MFLC system coupled to a Sciex 5500 QTrap. The method was validated according to (inter)‐national guidelines. MFLC allowed for separation of the mentioned analytes within 3 minutes and limits of quantification of 0.01 ng/mL. Validation criteria were fulfilled for all analytes. PK data could be calculated for LSD, iso‐LSD, and oxo‐HO‐LSD in all participants. Additionally, hydroxy‐LSD (HO‐LSD) and HO‐LSD glucuronide could be qualitatively detected and PK determined in 11 and 8 subjects, respectively. Nor‐LSD was only sporadically detected. Elimination half‐lives of iso‐LSD (median 12 h) and LSD metabolites (median 9, 7.4, 12, and 11 h for oxo‐HO‐LSD, HO‐LSD, HO‐LSD‐gluc, and nor‐LSD, respectively) exceeded those of LSD (median 4.2 h). However, screening for metabolites to increase detection windows in plasma seems not to be constructive due to their very low concentrations. Copyright © 2016 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/dta.2042

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Steuer, A. E., Poetzsch, M., Stock, L., Eisenbeiss, L., Schmid, Y., Liechti, M. E., & Kraemer, T.
Venue
Drug Testing and Analysis
Publisher
Wiley
Published
2016-08-10
Volume
9
Issue
5
Pages
788-797
ISSN
  • 1942-7603 (ISSN-L)
  • 1942-7611
OpenAlex
W2517871020
Cited by
41
References
4
FWCI
7.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.