Cited by 36Forensic Toxicology and Drug AnalysisCannabis and Cannabinoid ResearchAnalytical chemistry methods development

Ultra-Sensitive Measurements of 11-Nor-Δ9-Tetrahydrocannabinol-9-Carboxylic Acid in Oral Fluid by Microflow Liquid Chromatography–Tandem Mass Spectrometry Using a Benchtop Quadrupole/Orbitrap Mass Spectrometer

He, Xiang, Kozak, Marta, Nimkar, Subodh·2012·Analytical Chemistry

Abstract

Oral fluid has been gaining more acceptance as the alternative matrix for forensic toxicology. Currently, Δ(9)-tetrahydrocannabinol (THC) is used as the primary target for detecting cannabis use in oral fluid. Meanwhile, THC carboxylic acid (THCA) in oral fluid is reported as a more reliable marker for cannabis abuse as its presence does not come from passive exposure. An analytical method for simultaneous quantitation of THC and THCA will be efficient for toxicology laboratories. THCA quantitation is challenging due to its very low concentration in oral fluid. Recently reported liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based methods achieved sufficient sensitivity but involved complex sample preparation procedures. We aimed to develop a sensitive LC-MS/MS method for simultaneous quantitation of THC and THCA in oral fluid with low-flow liquid chromatography and a Q Exactive mass spectrometer, using offline sample preparation of oral fluid followed by microflow LC with online sample cleanup. The total runtime of the method was 12.5 min. The method had a lower limit of quantitation of 7.5 pg/mL and was linear from 7.5 to 300 pg/mL for THCA. The intra- and interbatch precision of the method ranged from 3.3% to 9.3% for THC and THCA.

Integrity signals

Registry

Crossref · 10.1021/ac3019476

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Recent advances have produced more efficient time-of-flight and single-stage Orbitrap instruments with improved linearity, resolution, and mass accuracy, which are critically important for food metabolome analysis.

    “Rapid advances in technology have led to a new generation of much more efficient time-of-flight and single-stage Orbitrap (Exactive; Thermo Scientific) instruments, offering improved linearity, resolution, and mass accuracy, which will be critically important for the analysis of the food metabolome (115).”

    From The food metabolome: a window over dietary exposure (2014) · cites this paper as [115]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
He, X., Kozak, M., & Nimkar, S.
Affiliations
ThermoFisher Scientific, 355 River Oaks Parkway, San Jose, California 95134, United States
Corresponding author
He, Xiang
Venue
Analytical Chemistry
Published
2012-08-27
Volume
84
Issue
18
Pages
7643-7647
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2319291470
Cited by
36
References
11
Citations by year
2025: 1 · 2022: 1 · 2021: 3 · 2019: 3 · 2017: 3 · 2016: 4 · 2015: 3 · 2014: 9 · 2013: 9
FWCI
9.39
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Health Sciences › Medicine › Pharmacology › Cannabis and Cannabinoid Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
Keywords
oral fluid, forensic toxicology, tandem mass spectrometry, simultaneous quantitation
MeSH terms
Adult, Chromatography, High Pressure Liquid, Female, Humans, Male, Middle Aged, Saliva, Dronabinol, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review