CoChat

Incorporation of natriuretic peptides with clinical risk scores to predict heart failure among individuals with dysglycaemia

Open access
Segar, Matthew W., Khan, Muhammad Shahzeb, Patel, Kershaw V., Vaduganathan, Muthiah, Kannan, Vaishnavi, Willett, Duwayne, Peterson, Eric, Tang, W.H. Wilson, Butler, Javed, Everett, Brendan M., Fonarow, Gregg C., Wang, Thomas J., McGuire, Darren K., Pandey, Ambarish · 2022 · European Journal of Heart Failure
Cited by 46

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Aims: To evaluate the performance of the WATCH‐DM risk score, a clinical risk score for heart failure (HF), in patients with dysglycaemia and in combination with natriuretic peptides (NPs). Methods and results: Adults with diabetes/pre‐diabetes free of HF at baseline from four cohort studies (ARIC, CHS, FHS, and MESA) were included. The machine learning‐ [WATCH‐DM(ml)] and integer‐based [WATCH‐DM(i)] scores were used to estimate the 5‐year risk of incident HF. Discrimination was assessed by Harrell's concordance index (C‐index) and calibration by the Greenwood–Nam–D'Agostino (GND) statistic. Improvement in model performance with the addition of NP levels was assessed by C‐index and continuous net reclassification improvement (NRI). Of the 8938 participants included, 3554 (39.8%) had diabetes and 432 (4.8%) developed HF within 5 years. The WATCH‐DM(ml) and WATCH‐DM(i) scores demonstrated high discrimination for predicting HF risk among individuals with dysglycaemia (C‐indices = 0.80 and 0.71, respectively), with no evidence of miscalibration (GND P ≥0.10). The C‐index of elevated NP levels alone for predicting incident HF among individuals with dysglycaemia was significantly higher among participants with low/intermediate (<13) vs. high (≥13) WATCH‐DM(i) scores [0.71 (95% confidence interval 0.68–0.74) vs. 0.64 (95% confidence interval 0.61–0.66)]. When NP levels were combined with the WATCH‐DM(i) score, HF risk discrimination improvement and NRI varied across the spectrum of risk with greater improvement observed at low/intermediate risk [WATCH‐DM(i) <13] vs. high risk [WATCH‐DM(i) ≥13] (C‐index = 0.73 vs. 0.71; NRI = 0.45 vs. 0.17). Conclusion: The WATCH‐DM risk score can accurately predict incident HF risk in community‐based individuals with dysglycaemia. The addition of NP levels is associated with greater improvement in the HF risk prediction performance among individuals with low/intermediate risk than those with high risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ejhf.2375

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Metadata

Authors
Segar, M. W., Khan, M. S., Patel, K. V., Vaduganathan, M., Kannan, V., Willett, D., Peterson, E., Tang, W. H. W., Butler, J., Everett, B. M., Fonarow, G. C., Wang, T. J., McGuire, D. K., & Pandey, A.
Venue
European Journal of Heart Failure
Published
2021-11-23
Volume
24
Issue
1
Pages
169-180
ISSN
  • 1388-9842 (ISSN-L)
  • 1879-0844
OpenAlex
W3211129163
Cited by
46
References
19
FWCI
4.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.