The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Carbon‐Nanotube Based Electrochemical Biosensors: A Review
Abstract
This review addresses recent advances in carbon‐nanotubes (CNT) based electrochemical biosensors. The unique chemical and physical properties of CNT have paved the way to new and improved sensing devices, in general, and electrochemical biosensors, in particular. CNT‐based electrochemical transducers offer substantial improvements in the performance of amperometric enzyme electrodes, immunosensors and nucleic‐acid sensing devices. The greatly enhanced electrochemical reactivity of hydrogen peroxide and NADH at CNT‐modified electrodes makes these nanomaterials extremely attractive for numerous oxidase‐ and dehydrogenase‐based amperometric biosensors. Aligned CNT “forests” can act as molecular wires to allow efficient electron transfer between the underlying electrode and the redox centers of enzymes. Bioaffinity devices utilizing enzyme tags can greatly benefit from the enhanced response of the biocatalytic‐reaction product at the CNT transducer and from CNT amplification platforms carrying multiple tags. Common designs of CNT‐based biosensors are discussed, along with practical examples of such devices. The successful realization of CNT‐based biosensors requires proper control of their chemical and physical properties, as well as their functionalization and surface immobilization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon Nanotubes--the Route Toward Applications
Baughman, R. H., Zakhidov, A. A., & de Heer, W. A. (2002) · Science · doi:10.1126/science.1060928 · Cited by 10,267
Functionalization of Single-Walled Carbon Nanotubes
Hirsch, A. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020603)41:11<1853::aid-anie1853>3.0.co;2-n · Cited by 2,146
Solubilization of Carbon Nanotubes by Nafion toward the Preparation of Amperometric Biosensors
Wang, J., Musameh, M., & Lin, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028951v · Cited by 1,382
Self-citationEnzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes
Musameh, M., Wang, J., Merkoci, A., & Lin, Y. (2002) · Electrochemistry Communications · doi:10.1016/s1388-2481(02)00451-4 · Cited by 1,066
Self-citationElectrochemical Biosensing Platforms Using Platinum Nanoparticles and Carbon Nanotubes
Hrapovic, S., Liu, Y., Male, K. B., & Luong, J. H. T. (2004) · Analytical Chemistry · doi:10.1021/ac035143t · Cited by 1,064
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Protein Electrochemistry Using Aligned Carbon Nanotube Arrays
Gooding, J. J., Wibowo, R., Liu, Yang, W., Losic, D., Orbons, S., Mearns, F. J., Shapter, J. G., & Hibbert, D. B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035722f · Cited by 881
Wang, J., Liu, G., & Jan, M. R. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031723w · Cited by 682
Self-citationDirect electron transfer of glucose oxidase on carbon nanotubes
Guiseppi-Elie, A., Lei, C., & Baughman, R. H. (2002) · Nanotechnology · doi:10.1088/0957-4484/13/5/303 · Cited by 629
Electrochemical Sensors Based on Carbon Nanotubes
Zhao, Q., Gan, Z., & Zhuang, Q. (2002) · Electroanalysis · doi:10.1002/elan.200290000 · Cited by 622
Long‐Range Electrical Contacting of Redox Enzymes by SWCNT Connectors
Patolsky, F., Weizmann, Y., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353275 · Cited by 609
Carbon Nanotube Purification: Preparation and Characterization of Carbon Nanotube Paste Electrodes
Valentini, F., Amine, A., Orlanducci, S., Terranova, M. L., & Palleschi, G. (2003) · Analytical Chemistry · doi:10.1021/ac0300237 · Cited by 540
Carbon paste electrodes modified with enzymes, tissues, and cells
Gorton, L. (1995) · Electroanalysis · doi:10.1002/elan.1140070104 · Cited by 515
Electrochemical DNA Hybridization Biosensors
Gooding, J. J. (2002) · Electroanalysis · doi:10.1002/1521-4109(200209)14:17<1149::aid-elan1149>3.0.co;2-8 · Cited by 480
Carbon nanotubes paste electrode
Rubianes, M. D., & Rivas, G. A. (2003) · Electrochemistry Communications · doi:10.1016/s1388-2481(03)00168-1 · Cited by 434
Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection
Cai, H., Cao, X., Jiang, Y., He, P., & Fang, Y. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-002-1652-9 · Cited by 431
Nonenzymatic glucose detection using multi-walled carbon nanotube electrodes
Ye, J.-S., Wen, Y., De Zhang, W., Ming Gan, L., Xu, G. Q., & Sheu, F.-S. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2003.10.013 · Cited by 325
Lin, Y., Lu, F., & Wang, J. (2004) · Electroanalysis · doi:10.1002/elan.200302933 · Cited by 315
Self-citationWang, J., Kawde, A.-N., & Musameh, M. (2003) · The Analyst · doi:10.1039/b303282e · Cited by 312
Self-citationChemical and Biochemical Sensing with Modified Single Walled Carbon Nanotubes
Davis, J. J., Coleman, K. S., Azamian, B. R., Bagshaw, C. B., & Green, M. L. H. (2003) · Chemistry – A European Journal · doi:10.1002/chem.200304872 · Cited by 299
Carbon nanotube screen-printed electrochemical sensors
Wang, J., & Musameh, M. (2004) · The Analyst · doi:10.1039/b313431h · Cited by 272
Self-citationAmperometric biosensors based on NAD(P)‐dependent dehydrogenase enzymes
Lobo, M. J., Miranda, A. J., & Tuñón, P. (1997) · Electroanalysis · doi:10.1002/elan.1140090302 · Cited by 204
Koehne, J., Chen, H., Li, J., Cassell, A. M., Ye, Q., Ng, H. T., Han, J., & Meyyappan, M. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/12/001 · Cited by 181
Cai, H. N., Xu, Y. C., He, P., & Fang, Y. (2003) · Electroanalysis · doi:10.1002/elan.200302755 · Cited by 131
Enzyme-dispersed carbon-nanotube electrodes: a needle microsensor for monitoring glucose
Wang, J., & Musameh, M. M. (2003) · The Analyst · doi:10.1039/b309928h · Cited by 115
Self-citationLuong, J. H. T., Hrapovic, S., Wang, D., Bensebaa, F., & Simard, B. (2004) · Electroanalysis · doi:10.1002/elan.200302931 · Cited by 115
Study of carbon nanotubes–HRP modified electrode and its application for novel on-line biosensors
Yamamoto, K., Shi, G., Zhou, T., Xu, F., Xu, J., Kato, T., Jin, J., & Jin, L. (2003) · The Analyst · doi:10.1039/b209698f · Cited by 95
Cited by
Honeycomb Carbon: A Review of Graphene
Allen, M. J., Tung, V. C., & Kaner, R. B. (2010) · Chemical Reviews · doi:10.1021/cr900070d · Cited by 6,998
Tasis, D., Tagmatarchis, N., Bianco, A., & Prato, M. (2006) · Chemical Reviews · doi:10.1021/cr050569o · Cited by 4,273
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Self-citationGraphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Self-citationScience and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Metadata
- Authors
- Wang, J.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 17
- Issue
- 1
- Pages
- 7-14
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W1982904490
- Cited by
- 2,387
- References
- 28
- FWCI
- 56.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.