The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Nanowire‐Based Electrochemical Biosensors
Abstract
We review recent advances in biosensors based on one‐dimensional (1‐D) nanostructure field‐effect transistors (FET). Specifically, we address the fabrication, functionalization, assembly/alignment and sensing applications of FET based on carbon nanotubes, silicon nanowires and conducting polymer nanowires. The advantages and disadvantages of various fabrication, functionalization, and assembling procedures of these nanosensors are reviewed and discussed. We evaluate how they have been used for detection of various biological molecules and how such devices have enabled the achievement of high sensitivity and selectivity with low detection limits. Finally, we conclude by highlighting some of the challenges researchers face in the 1‐D nanostructures research arena and also predict the direction toward which future research in this area might be directed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Nanofibers for Biomedical and Healthcare Applications
Rasouli, R., Barhoum, A., Bechelany, M., & Dufresne, A. (2019) · Macromolecular Bioscience · doi:10.1002/mabi.201800256 · Cited by 319
Functionalized carbon nanotubes and nanofibers for biosensing applications
Wang, J., & Lin, Y. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.05.009 · Cited by 289
Design of highly porous SnO2-CuO nanotubes for enhancing H2S gas sensor performance
Park, K.-R., Cho, H.-B., Lee, J., Song, Y., Kim, W.-B., & Choa, Y.-H. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.127179 · Cited by 260
Supraja, P., Sudarshan, V., Tripathy, S., Agrawal, A., & Singh, S. G. (2019) · Analytical Methods · doi:10.1039/c8ay02617c · Cited by 45
Metadata
- Authors
- Wanekaya, A. K., Chen, W., Myung, N. V., & Mulchandani, A.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2006-03
- Volume
- 18
- Issue
- 6
- Pages
- 533-550
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2056225348
- Cited by
- 481
- References
- 2
- FWCI
- 33.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanowire‐Based Electrochemical Biosensors. https://app.cochat.ai/papers/10.1002/elan.200503449
- The paper
- Wanekaya, A. K., Chen, W., Myung, N. V., & Mulchandani, A. (2006). Nanowire‐Based Electrochemical Biosensors. Electroanalysis. https://doi.org/10.1002/elan.200503449
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.