The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Micro‐ and Nano‐ Magnetic Particles for Applications in Biosensing
Abstract
This article reviews the development of electrochemical biosensors, incorporating magnetic particles, for detecting biomolecules (nucleic acids and proteins) and cells. Magnetic particles (MPs) of micro‐ and nanoscale, mimicking the size of molecules in nature, possess interesting characteristics that facilitate the purification and detection of biomolecules in a wide range of samples. In particular, the high surface area and the paramagnetic or superparamagnetic properties of these tiny particles provide an attractive technology platform for the design of electrochemical biosensors. Examples of electrochemistry‐based approaches to achieve the separation and detection of bioentities utilizing MPs are described. Emphasis is placed on the strategies to incorporate the electrochemical labels to the MPs and the methods to achieve the dual function of electrochemical detection and magnetic separation. The protocols to make MPs as labels in biological sensors are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Lanciotti, R. S., & Kerst, A. J. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.12.4506-4513.2001 · Cited by 267
Fox, J. D., Han, S., Samuelson, A., Zhang, Y., Neale, M. L., & Westmoreland, D. (2002) · Journal of Clinical Virology · doi:10.1016/s1386-6532(01)00241-4 · Cited by 84
Cited by
Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene
Shan, C., Yang, H., Song, J., Han, D., Ivaska, A., & Niu, L. (2009) · Analytical Chemistry · doi:10.1021/ac802193c · Cited by 1,315
Graphene/AuNPs/chitosan nanocomposites film for glucose biosensing
Shan, C., Yang, H., Han, D., Zhang, Q., Ivaska, A., & Niu, L. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.024 · Cited by 788
Nguyen, M. D., Tran, H.-V., Xu, S., & Lee, T. R. (2021) · Applied Sciences · doi:10.3390/app112311301 · Cited by 783
Magnetic Nanoparticles: From Design and Synthesis to Real World Applications
Kudr, J., Haddad, Y., Richtera, L., Heger, Z., Cernak, M., Adam, V., & Zitka, O. (2017) · Nanomaterials · doi:10.3390/nano7090243 · Cited by 628
Enzyme-based logic systems for information processing
Katz, E., & Privman, V. (2010) · Chemical Society Reviews · doi:10.1039/b806038j · Cited by 491
Yuan, P., Liu, D., Fan, M., Yang, D., Zhu, R., Ge, F., Zhu, J., & He, H. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.08.129 · Cited by 380
Magnetically actuated propulsion at low Reynolds numbers: towards nanoscale control
Fischer, P., & Ghosh, A. (2011) · Nanoscale · doi:10.1039/c0nr00566e · Cited by 292
Polymeric nanofibers for the removal of Cr(III) from tannery waste water
El-Sherif, I. Y., Tolani, S., Ofosu, K., Mohamed, O. A., & Wanekaya, A. K. (2013) · Journal of Environmental Management · doi:10.1016/j.jenvman.2013.08.004 · Cited by 72
Metadata
- Authors
- Hsing, I., Xu, Y., & Zhao, W.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2007-04
- Volume
- 19
- Issue
- 7-8
- Pages
- 755-768
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2000956027
- Cited by
- 216
- References
- 3
- FWCI
- 14.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.