The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Detection of Trace Heavy Metal Ions Using Carbon Nanotube‐ Modified Electrodes
Abstract
A sensitive voltammetric method for detection of trace heavy metal ions using chemically modified carbon nanotubes (CNTs) electrode surfaces is described. The CNTs were covalently modified with cysteine prior to casting on electrode surfaces. Cysteine is an amino acid with high affinities towards some heavy metals. In this assay, heavy metals ions accumulated on the cysteine‐modified CNT electrode surfaces prior to being subjected to differential pulse anodic stripping voltammetry analysis. The resulting peak currents were linearly related to the concentrations of the metal ions. The method was optimized with respect to accumulation time, reduction time and reduction potential. The detection limits were found to be 1 ppb and 15 ppb for Pb 2+ and Cu 2+ respectively. The technique was used for the detection of Pb 2+ and Cu 2+ in spiked lake water. The average recoveries of Pb 2+ and Cu 2+ were 96.2% and 94.5% with relative standard deviations of 8.43% and 7.53% respectively. The potential for simultaneous detection of heavy metal ions by the modified CNTs was also demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Modulation of p53, ErbB1, ErbB2, and Raf-1 Expression in Lung Cancer Cells by Depsipeptide FR901228
Yu, X. (2002) · CancerSpectrum Knowledge Environment · doi:10.1093/jnci/94.7.504 · Cited by 360
Cited by
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Nanostructured Sensors for Detection of Heavy Metals: A Review
Li, M., Gou, H., Al-Ogaidi, I., & Wu, N. (2013) · ACS Sustainable Chemistry & Engineering · doi:10.1021/sc400019a · Cited by 606
Recent applications of carbon-based nanomaterials in analytical chemistry: Critical review
Scida, K., Stege, P. W., Haby, G., Messina, G. A., & García, C. D. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.02.025 · Cited by 432
Gao, C., Guo, Z., Liu, J.-H., & Huang, X.-J. (2012) · Nanoscale · doi:10.1039/c2nr11757f · Cited by 424
Carbon Nanomaterials: Synthesis, Functionalization and Sensing Applications
Speranza, G. (2021) · Nanomaterials · doi:10.3390/nano11040967 · Cited by 418
Metadata
- Authors
- Morton, J., Havens, N., Mugweru, A., & Wanekaya, A. K.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2009-07
- Volume
- 21
- Issue
- 14
- Pages
- 1597-1603
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2020817023
- Cited by
- 178
- References
- 2
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.