The DOI matches its Crossref record.
Colloidal carriers for intravenous drug targeting: Plasma protein adsorption patterns on surface‐modified latex particles evaluated by two‐dimensional polyacrylamide gel electrophoresis
Open accessAbstract
Targeting to specific sites of the body via colloidal carriers is sought in order to reduce drug side effects. The adsorption of plasma proteins on intravenously injected particles is regarded as the key factor in explaining their organ distribution: total bound protein, or, more likely, the presence of specific proteins and their conformation, are expected to influence macrophage uptake. Polystyrene beads, 60 nm in diameter, were used as model carriers; their surface was differentially modified by adsorption of increasingly hydrophilic block copolymers, poloxamers 184, 188 and 407. After incubation in plasma, the patterns of protein adsorption onto coated beads were analyzed by high‐resolution two‐dimensional polyacrylamide gel electrophoresis (2‐D PAGE). The behavior of some representative proteins was monitored, including albumin, fibrinogen, IgG, factor B and the apolipoproteins, A‐I, A‐IV, C‐III, E and J. The more hydrophobic the particles, the larger the total amount of bound protein. However, this correlation was not valid for all of the analyzed protein species, which proves that it is insufficient to look only at physico‐chemical data to predict organ distribution. On the contrary, it is essential to use 2‐D PAGE to establish the correlation between adsorbed proteins and carrier behavior in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Opsonization, biodistribution, and pharmacokinetics of polymeric nanoparticles
OWENSIII, D., & PEPPAS, N. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.10.010 · Cited by 3,637
Cedervall, T., Lynch, I., Lindman, S., Berggård, T., Thulin, E., Nilsson, H., Dawson, K. A., & Linse, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608582104 · Cited by 3,281
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Aggarwal, P., Hall, J. B., McLeland, C. B., Dobrovolskaia, M. A., & McNeil, S. E. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.03.009 · Cited by 1,791
Walkey, C. D., & Chan, W. C. W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15233e · Cited by 1,758
Metadata
- Authors
- Blunk, T., Hochstrasser, D. F., Sanchez, J., Müller, B. W., & Müller, R. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 14
- Issue
- 1
- Pages
- 1382-1387
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2140897179
- Cited by
- 251
- References
- 0
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colloidal carriers for intravenous drug targeting: Plasma protein adsorption patterns on surface‐modified latex particles evaluated by two‐dimensional polyacrylamide gel electrophoresis. https://app.cochat.ai/papers/10.1002/elps.11501401214
- The paper
- Blunk, T., Hochstrasser, D. F., Sanchez, J., Müller, B. W., & Müller, R. H. (1993). Colloidal carriers for intravenous drug targeting: Plasma protein adsorption patterns on surface‐modified latex particles evaluated by two‐dimensional polyacrylamide gel electrophoresis. ELECTROPHORESIS. https://doi.org/10.1002/elps.11501401214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.