A highly discriminating octoplex short tandem repeat polymerase chain reaction system suitable for human individual identification
The DOI matches its Crossref record.
Abstract
Through the use of fluorescence‐based polymerase chain reaction systems, a highly discriminating multiplex with the potential for individual identification has been developed. The use of multiple dye technology enabling loci with overlapping size ranges to be co‐amplified has enabled us to successfully amplify seven tetranucleotide short tandem repeat loci within a single reaction in a discriminating power in the region of 1 × 10 9. Three out of the seven loci employed exhibit alleles differing in size by only 2 bp as opposed to the conventional 4 bp, which results in such loci being more powerful in terms of distinguishing between samples, particularly when co‐amplified in this manner. The size ranges of the loci contained within the system are such that windows still exist for the inclusion of additional loci at a later stage, which could increase the discriminating power of the system still further. In addition, further weight and utility is lent to the system through the incorporation of a simple and reliable sex test involving the amplification of a segment of the X–Y homologous gene Amelogenin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schweppe, R. E., Klopper, J. P., Korch, C., Pugazhenthi, U., Benezra, M., Knauf, J. A., Fagin, J. A., Marlow, L. A., Copland, J. A., Smallridge, R. C., et al. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1102 · Cited by 563
Short tandem repeat profiling provides an international reference standard for human cell lines
Masters, J. R., Thomson, J. A., Daly-Burns, B., Reid, Y. A., Dirks, W. G., Packer, P., Toji, L. H., Ohno, T., Tanabe, H., Arlett, C. F., et al. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.121616198 · Cited by 478
STR allele sequence variation: Current knowledge and future issues
Gettings, K. B., Aponte, R. A., Vallone, P. M., & Butler, J. M. (2015) · Forensic Science International Genetics · doi:10.1016/j.fsigen.2015.06.005 · Cited by 205
“Science Service, D8S1179 is listed as D6S502 because of a labeling error in the Cooperative Human Linkage Center database from which this STR was chosen [67,68].”
BackgroundDNA fingerprinting of the NCI-60 cell line panel
Lorenzi, P. L., Reinhold, W. C., Varma, S., Hutchinson, A. A., Pommier, Y., Chanock, S. J., & Weinstein, J. N. (2009) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-08-0921 · Cited by 166
“An inexpensive, standardized technique was developed for forensic and paternity applications based on short tandem repeat (STR) profiling of those hypervariable DNA regions (25), and it is now commonly employed for cell line characterization (26, 27).”
MethodEssential role for gene profiling analysis in the authentication of human cell lines
YOSHINO, K., IIMURA, E., SAIJO, K., IWASE, S., FUKAMI, K., OHNO, T., OBATA, Y., & NAKAMURA, Y. (2006) · Human Cell · doi:10.1111/j.1749-0774.2005.00007.x · Cited by 44
The Use of Short Tandem Repeat Profiling to Characterize Human Bladder Cancer Cell Lines
Chiong, E., Dadbin, A., Harris, L. D., Sabichi, A. L., & Grossman, H. B. (2009) · Journal of Urology · doi:10.1016/j.juro.2009.01.108 · Cited by 20
Metadata
- Authors
- Oldroyd, N. J., Urquhart, A. J., Kimpton, C. P., Millican, E. S., Watson, S. K., Downes, T., & Gill, P. D.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 16
- Issue
- 1
- Pages
- 334-337
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2041731495
- Cited by
- 101
- References
- 0
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.