Effect of protein application mode and acrylamide concentration on the resolution of protein spots separated by two‐dimensional gel electrophoresis
The DOI matches its Crossref record.
Abstract
Two‐dimensional gel electrophoresis separates large numbers of proteins in two steps on the basis of differences in their p I s and molecular masses. The separation is usually performed on immobilized pH gradient strips, followed by gradient polyacrylamide gels separating proteins with molecular masses between 5–200 kDa. For the first‐dimensional separation the protein samples are usually applied near one end of the strip. Using total soluble protein extracts of the bacterium Haemophilus influenzae, we found that simultaneous sample application at both the basic and the acidic ends of the strip resulted in detection of more and stronger protein spots in comparison with sample application at one end only. Because many proteins of an organism have similar p I and Mr values, an overlapping of protein spots is frequently observed in the second‐dimensional separation. The soluble protein fraction of H. influenzae was further separated on gels of constant acrylamide concentration between 7.5% and 15.0%. We found that for proteins of molecular mass within certain ranges, the gels of homogeneous acrylamide concentration provided more efficient spot separation than the gradient gels. The observed improvements in spot resolution may be useful in the characterization of proteins from other organisms or cell lines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrolysis and amino acid composition analysis of proteins
Fountoulakis, M., & Lahm, H.-W. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00721-3 · Cited by 606
Self-citationAberrant expression of peroxiredoxin subtypes in neurodegenerative disorders
Krapfenbauer, K., Engidawork, E., Cairns, N., Fountoulakis, M., & Lubec, G. (2003) · Brain Research · doi:10.1016/s0006-8993(02)04243-9 · Cited by 287
Self-citationProteomics in brain research: potentials and limitations
Lubec, G., Krapfenbauer, K., & Fountoulakis, M. (2003) · Progress in Neurobiology · doi:10.1016/s0301-0082(03)00036-4 · Cited by 163
Self-citationVlkolinský, R., Cairns, N., Fountoulakis, M., & Lubec, G. (2001) · Neurobiology of Aging · doi:10.1016/s0197-4580(01)00218-4 · Cited by 95
Self-citationChen, G., Racay, P., Bichet, S., Celio, M. R., Eggli, P., & Schwaller, B. (2006) · Neuroscience · doi:10.1016/j.neuroscience.2006.06.008 · Cited by 47
Metadata
- Authors
- Langen, H., Röder, D., Juranville, J., & Fountoulakis, M.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 18
- Issue
- 11
- Pages
- 2085-2090
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2068250844
- Cited by
- 130
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).