Cited by 606Analytical Chemistry and ChromatographyAdvanced Proteomics Techniques and ApplicationsFood and Agricultural Sciences

Hydrolysis and amino acid composition analysis of proteins

Fountoulakis, Michael, Lahm, Hans-Werner·1998·Journal of Chromatography A

Abstract

Amino acid composition analysis is a classical protein analysis method, which finds a wide application in medical and food science research and is indispensable for protein quantification. It is a complex technique, comprising two steps, hydrolysis of the substrate and chromatographic separation and detection of the residues. A properly performed hydrolysis is a prerequisite of a successful analysis. The most significant developments of the technology in the last decade consist in the (i) reduction of the hydrolysis time by the use of microwave radiation energy; (ii) improvement in the sensitivity of the residue detection, the quantification of the sensitive residues and separation of the enantiomeric forms of the amino acids; (iii) application of amino acid analysis in the large-scale protein identification by database search; and (iv) gradual replacement of the original ion exchange residue separation by reversed-phase high-performance liquid chromatography. Amino acid analysis is currently facing an enormous competition in the determination of the identity of proteins and amino acid homologs by the essentially faster mass spectrometry techniques. The amino acid analysis technology needs further simplification and automation of the hydrolysis, chromatography and detection steps to withstand the pressure exerted by the other technologies.

Integrity signals

Registry

Crossref · 10.1016/s0021-9673(98)00721-3

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Acid hydrolysis conditions lead to loss of cysteine, cystine, and some tryptophan species, whereas alkaline conditions preserve tryptophan species but break down arginine, serine, threonine and cysteine.

    “Acid hydrolysis conditions lead to a loss of cysteine, cystine, and some tryptophan species, whereas alkaline conditions preserve tryptophan species, but breaks down arginine, serine, threonine and cysteine [107].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fountoulakis, M., & Lahm, H.-W.
Affiliations
F. Hoffmann-La Roche AG (CH)
Corresponding author
Fountoulakis, Michael
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
1998-11
Volume
826
Issue
2
Pages
109-134
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2046914949
Cited by
606
References
2
Citations by year
2026: 24 · 2025: 29 · 2024: 38 · 2023: 32 · 2022: 32 · 2021: 27 · 2020: 39 · 2019: 50 · 2018: 51 · 2017: 38 · 2016: 31 · 2015: 30 · 2014: 17 · 2013: 26 · 2012: 25
FWCI
0.48
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Food and Agricultural Sciences
Keywords
proteolysis, microwave-assisted hydrolysis, amino acid quantification, enantiomer separation, reversed-phase HPLC, ion-exchange chromatography, protein identification, mass spectrometry comparison
MeSH terms
Amino Acids, Chromatography, High Pressure Liquid, Chromatography, Ion Exchange, Hydrolysis, Proteins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review