CoChat

Genotyping of forensic short tandem repeat (STR) systems based on sizing precision in a capillary electrophoresis instrument

Lazaruk, Katherine, Walsh, P. Sean, Oaks, Frank, Gilbert, Dennis, Rosenblum, Barnett B., Menchen, Steve, Scheibler, Don, Wenz, H. Michael, Holt, Cydne, Wallin, Jeanette · 1998 · ELECTROPHORESIS
Cited by 155

The DOI matches its Crossref record.

Abstract

Automated fluorescence analysis of polymerase chain reaction (PCR)‐amplified short tandem repeat (STR) systems by capillary electrophoresis (CE) is becoming an established tool both in forensic casework and in the implementation of both state and national convicted offender DNA databases. A new capillary electrophoresis instrument, the ABI Prism 310 Genetic Analyzer, along with the Performance Optimized Polymer 4 (POP‐4) provides an automated and precise method for simultaneously analyzing ten flourescently labeled STR loci from a single PCR amplification kit, which provides a power of discrimination of approximately one in five billion from a single PCR amplification. Data are presented on sizing precision, sizing accuracy, and resolution for the STR loci in the Amp Fl STR Profiler™ kit. Sizing accuracy is highly dependent on the electrophoresis system, and therefore the reporting of alleles based on the nucleotide size obtained from an electrophoresis system is not recommended for forensic work. The precision of the 310 capillary electrophoresis system, coupled with software developed for automated genotyping of alleles based on the use of an allelie ladder, allows for accurate genotyping of STR loci. Sizing precision of ⩽ 0.16 nucleotide standard deviation was obtained with this system, thus allowing for accurate genotyping of length variants that differ in length by a single nucleotide.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.1150190116

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 155

Metadata

Authors
Lazaruk, K., Walsh, P. S., Oaks, F., Gilbert, D., Rosenblum, B. B., Menchen, S., Scheibler, D., Wenz, H. M., Holt, C., & Wallin, J.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
1998-01
Volume
19
Issue
1
Pages
86-93
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W1993935432
Cited by
155
References
0
FWCI
7.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Genotyping of forensic short tandem repeat (STR) systems based on sizing precision in a capillary electrophoresis instrument. https://app.cochat.ai/papers/10.1002/elps.1150190116
The paper
Lazaruk, K., Walsh, P. S., Oaks, F., Gilbert, D., Rosenblum, B. B., Menchen, S., Scheibler, D., Wenz, H. M., Holt, C., & Wallin, J. (1998). Genotyping of forensic short tandem repeat (STR) systems based on sizing precision in a capillary electrophoresis instrument. ELECTROPHORESIS. https://doi.org/10.1002/elps.1150190116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.