Proteome analysis of human liver tumor tissue by two‐dimensional gel electrophoresis and matrixassisted laser desorption/ionization‐mass spectrometry for identification of disease‐related proteins

Kim, Jina, Kim, Soon H., Lee, Seung U., Ha, Geun H., Kang, Deok G., Ha, Na‐Young, Ahn, Jin S., Cho, Hey Y., Kang, Sung‐Jo, Lee, Young‐Joon, Hong, Soon C., Ha, Woo S., Bae, Jong M., Lee, Chang‐Won, Kim, Jae W. · 2002 · ELECTROPHORESIS
Cited by 117

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Hepatocellular carcinoma (HCC) is a common malignancy worldwide and is a leading cause of death. To contribute to the development and improvement of molecular markers for diagnostics and prognostics and of therapeutic targets for the disease, we have largely expanded the currently available human liver tissue maps and studied the differential expression of proteins in normal and cancer tissues. Reference two‐dimensional electrophoresis (2‐DE) maps of human liver tumor tissue include labeled 2‐DE images for total homogenate and soluble fraction separated on pH 3–10 gels, and also images for soluble fraction separated on pH 4–7 and pH 6–9 gels for a more detailed map. Proteins were separated in the first dimension by isoelectric focusing on immobilized pH gradient (IPG) strips, and by 7.5–17.5% gradient sodium dodecyl sulfate‐polyacrylamide gel electrophoresis (SDS‐PAGE) gels in the second dimension. Protein identification was done by peptide mass fingerprinting with delayed extraction‐matrix assisted laser desorption/ionization‐time of flight‐mass spectrometry (DE‐MALDI‐TOF‐MS). In total, 212 protein spots (117 spots in pH 4–7 map and 95 spots in pH 6–9) corresponding to 127 different polypeptide chains were identified. In the next step, we analyzed the differential protein expression of liver tumor samples, to find out candidates for liver cancer‐associated proteins. Matched pairs of tissues from 11 liver cancer patients were analyzed for their 2‐DE profiles. Protein expression was comparatively analyzed by use of image analysis software. Proteins whose expression levels were different by more than three‐fold in at least 30% (four) of the patients were further analyzed. Numbers of protein spots overexpressed or underexpressed in tumor tissues as compared with nontumorous regions were 9 and 28, respectively. Among these 37 spots, 1 overexpressed and 15 underexpressed spots, corresponding to 11 proteins, were identified. The physiological significance of the differential expressions is discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.200290032

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 117

Metadata

Authors
Kim, J., Kim, S. H., Lee, S. U., Ha, G. H., Kang, D. G., Ha, N., Ahn, J. S., Cho, H. Y., Kang, S., Lee, Y., Hong, S. C., Ha, W. S., Bae, J. M., Lee, C., & Kim, J. W.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2002-12
Volume
23
Issue
24
Pages
4142-4156
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2058265375
Cited by
117
References
1
FWCI
6.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.