The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Microfluidic systems in proteomics
Open accessAbstract
We present the state‐of‐the‐art in miniaturized sample preparation, immunoassays, one‐dimensional and multidimensional analyte separations, and coupling of microdevices with electrospray ionization‐mass spectrometry. Hyphenation of these different techniques and their relevance to proteomics will be discussed. In particular, we will show that analytical performances of microfluidic analytical systems are already close to fulfill the requirements for proteomics, and that miniaturization results at the same time in a dramatic increase in analysis throughput. Throughout this review, some examples of analytical operations that cannot be achieved without microfluidics will be emphasized. Finally, conditions for the spreading of microanalytical systems in routine proteomic labs will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Light-Directed, Spatially Addressable Parallel Chemical Synthesis
Fodor, S. P. A., Read, J. L., Pirrung, M. C., Stryer, L., Lu, A. T., & Solas, D. (1991) · Science · doi:10.1126/science.1990438 · Cited by 2,696
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Evaluation of two-dimensional gel electrophoresis-based proteome analysis technology
Gygi, S. P., Corthals, G. L., Zhang, Y., Rochon, Y., & Aebersold, R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.160270797 · Cited by 1,319
A proteomic view of the Plasmodium falciparum life cycle
Florens, L., Washburn, M. P., Raine, J. D., Anthony, R. M., Grainger, M., Haynes, J. D., Moch, J. K., Muster, N., Sacci, J. B., Tabb, D. L., et al. (2002) · Nature · doi:10.1038/nature01107 · Cited by 1,308
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Separation of Long DNA Molecules in a Microfabricated Entropic Trap Array
Han, J., & Craighead, H. G. (2000) · Science · doi:10.1126/science.288.5468.1026 · Cited by 924
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Rabilloud, T. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200201)2:1<3::aid-prot3>3.0.co;2-r · Cited by 717
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Developments and new applications of UV-induced surface graft polymerizations
DENG, J., WANG, L., LIU, L., & YANG, W. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.06.002 · Cited by 465
Biofilms in Endodontics—Current Status and Future Directions
Neelakantan, P., Romero, M., Vera, J., Daood, U., Khan, A., Yan, A., & Cheung, G. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18081748 · Cited by 253
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Metadata
- Authors
- Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., Rossier, J. S., Przybylski, M., & Girault, H. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 24
- Issue
- 21
- Pages
- 3533-3562
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2053766086
- Cited by
- 262
- References
- 102
- FWCI
- 20.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.