The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Microfluidic systems in proteomics
Open accessAbstract
We present the state‐of‐the‐art in miniaturized sample preparation, immunoassays, one‐dimensional and multidimensional analyte separations, and coupling of microdevices with electrospray ionization‐mass spectrometry. Hyphenation of these different techniques and their relevance to proteomics will be discussed. In particular, we will show that analytical performances of microfluidic analytical systems are already close to fulfill the requirements for proteomics, and that miniaturization results at the same time in a dramatic increase in analysis throughput. Throughout this review, some examples of analytical operations that cannot be achieved without microfluidics will be emphasized. Finally, conditions for the spreading of microanalytical systems in routine proteomic labs will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Light-Directed, Spatially Addressable Parallel Chemical Synthesis
Fodor, S. P. A., Read, J. L., Pirrung, M. C., Stryer, L., Lu, A. T., & Solas, D. (1991) · Science · doi:10.1126/science.1990438 · Cited by 2,696
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Evaluation of two-dimensional gel electrophoresis-based proteome analysis technology
Gygi, S. P., Corthals, G. L., Zhang, Y., Rochon, Y., & Aebersold, R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.160270797 · Cited by 1,319
A proteomic view of the Plasmodium falciparum life cycle
Florens, L., Washburn, M. P., Raine, J. D., Anthony, R. M., Grainger, M., Haynes, J. D., Moch, J. K., Muster, N., Sacci, J. B., Tabb, D. L., et al. (2002) · Nature · doi:10.1038/nature01107 · Cited by 1,308
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Separation of Long DNA Molecules in a Microfabricated Entropic Trap Array
Han, J., & Craighead, H. G. (2000) · Science · doi:10.1126/science.288.5468.1026 · Cited by 924
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Rabilloud, T. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200201)2:1<3::aid-prot3>3.0.co;2-r · Cited by 717
Schuck, P. (1997) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.26.1.541 · Cited by 657
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
The dynamic range of protein expression: A challenge for proteomic research
Corthals, G. L., Wasinger, V. C., Hochstrasser, D. F., & Sanchez, J.-C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1104::aid-elps1104>3.0.co;2-c · Cited by 619
McDonnell, J. M. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00251-9 · Cited by 594
Surface Plasmon Resonance Imaging Measurements of Ultrathin Organic Films
Brockman, J. M., Nelson, B. P., & Corn, R. M. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.41 · Cited by 551
Two-dimensional separations: concept and promise
Giddings, J. C. (1984) · Analytical Chemistry · doi:10.1021/ac00276a003 · Cited by 537
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
Self-Assembled Magnetic Matrices for DNA Separation Chips
Doyle, P. S., Bibette, J., Bancaud, A., & Viovy, J. (2002) · Science · doi:10.1126/science.1068420 · Cited by 484
Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
High-Speed Separations on a Microchip
Jacobson, S. C., Hergenroder, R., Koutny, L. B., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a029 · Cited by 450
Chiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
A rapid diffusion immunoassay in a T-sensor
Hatch, A., Kamholz, A. E., Hawkins, K. R., Munson, M. S., Schilling, E. A., Weigl, B. H., & Yager, P. (2001) · Nature Biotechnology · doi:10.1038/88135 · Cited by 383
Southern, E. M., Maskos, U., & Elder, J. K. (1992) · Genomics · doi:10.1016/0888-7543(92)90014-j · Cited by 377
Choi, J.-W., Oh, K. W., Thomas, J. H., Heineman, W. R., Halsall, H. B., Nevin, J. H., Helmicki, A. J., Henderson, H. T., & Ahn, C. H. (2002) · Lab on a Chip · doi:10.1039/b107540n · Cited by 364
Yu, C., Davey, M. H., Svec, F., & Fréchet, J. M. J. (2001) · Analytical Chemistry · doi:10.1021/ac0106288 · Cited by 354
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac9610671 · Cited by 350
Peterson, D. S., Rohr, T., Svec, F., & Fréchet, J. M. J. (2002) · Analytical Chemistry · doi:10.1021/ac020180q · Cited by 345
Yakovleva, J., Davidsson, R., Lobanova, A., Bengtsson, M., Eremin, S., Laurell, T., & Emnéus, J. (2002) · Analytical Chemistry · doi:10.1021/ac015645b · Cited by 330
Surface Plasmon Resonance-Based Immunoassays
Mullett, W. M., Lai, E. P. C., & Yeung, J. M. (2000) · Methods · doi:10.1006/meth.2000.1039 · Cited by 322
Microchip Electrophoretic Immunoassay for Serum Cortisol
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M. (1996) · Analytical Chemistry · doi:10.1021/ac9508311 · Cited by 315
Schilling, E. A., Kamholz, A. E., & Yager, P. (2002) · Analytical Chemistry · doi:10.1021/ac015640e · Cited by 299
A Fully Integrated Monolithic Microchip Electrospray Device for Mass Spectrometry
Schultz, G. A., Corso, T. N., Prosser, S. J., & Zhang, S. (2000) · Analytical Chemistry · doi:10.1021/ac000325y · Cited by 284
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
Lagally, E. T., Emrich, C. A., & Mathies, R. A. (2001) · Lab on a Chip · doi:10.1039/b109031n · Cited by 284
Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R. (2001) · Analytical Chemistry · doi:10.1021/ac0012492 · Cited by 283
Microchannel wall coatings for protein separations by capillary and chip electrophoresis
Doherty, E. A. S., Meagher, R. J., Albarghouthi, M. N., & Barron, A. E. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200390029 · Cited by 281
Chiem, N. H., & Harrison, D. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.591 · Cited by 264
Paegel, B. M., Emrich, C. A., Wedemayer, G. J., Scherer, J. R., & Mathies, R. A. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012608699 · Cited by 263
Gao, J., Xu, J., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001126h · Cited by 257
Advances in protein solubilisation for two-dimensional electrophoresis
Herbert, B. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19990101)20:4/5<660::aid-elps660>3.0.co;2-q · Cited by 253
A Polymeric Microfluidic Chip for CE/MS Determination of Small Molecules
Kameoka, J., Craighead, H. G., Zhang, H., & Henion, J. (2001) · Analytical Chemistry · doi:10.1021/ac001533t · Cited by 224
Microfabricated Devices for Capillary Electrophoresis−Electrospray Mass Spectrometry
Zhang, B., Liu, H., Karger, B. L., & Foret, F. (1999) · Analytical Chemistry · doi:10.1021/ac990090u · Cited by 218
Microfabrication techniques for chemical/biosensors
Hierlemann, A., Brand, O., Hagleitner, C., & Baltes, H. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813583 · Cited by 212
Two-Dimensional Electrochromatography/Capillary Electrophoresis on a Microchip
Gottschlich, N., Jacobson, S. C., Culbertson, C. T., & Ramsey, J. M. (2001) · Analytical Chemistry · doi:10.1021/ac001019n · Cited by 208
Focus. Dealing with ‘real’ samples: sample pre-treatment in microfluidic systems
de Mello, A. J., & Beard, N. (2003) · Lab Chip · doi:10.1039/b301019h · Cited by 207
Wang, C., Oleschuk, R., Ouchen, F., Li, J., Thibault, P., & Harrison, D. J. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000815)14:15<1377::aid-rcm31>3.0.co;2-2 · Cited by 204
Herbert, B. R., & Righetti, P. G. (2000) · Electrophoresis · Cited by 203
Dodge, A., Fluri, K., Verpoorte, E., & de Rooij, N. F. (2001) · Analytical Chemistry · doi:10.1021/ac0015366 · Cited by 199
A microfluidic system for high-speed reproducible DNA sizing and quantitation
Mueller, O., Hahnenberger, K., Dittmann, M., Yee, H., Dubrow, R., Nagle, R., & Ilsley, D. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<128::aid-elps128>3.0.co;2-m · Cited by 197
A Microfabricated Fluidic Device for Performing Two-Dimensional Liquid-Phase Separations
Rocklin, R. D., Ramsey, R. S., & Ramsey, J. M. (2000) · Analytical Chemistry · doi:10.1021/ac000578r · Cited by 196
A Micromachined Chip-Based Electrospray Source for Mass Spectrometry
Licklider, L., Wang, X.-Q., Desai, A., Tai, Y.-C., & Lee, T. D. (2000) · Analytical Chemistry · doi:10.1021/ac990967p · Cited by 194
Microfluidic Assays of Acetylcholinesterase Inhibitors
Hadd, A. G., Jacobson, S. C., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990591f · Cited by 193
High-Efficiency, Two-Dimensional Separations of Protein Digests on Microfluidic Devices
Ramsey, J. D., Jacobson, S. C., Culbertson, C. T., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0264574 · Cited by 190
Li, J., Thibault, P., Bings, N. H., Skinner, C. D., Wang, C., Colyer, C., & Harrison, J. (1999) · Analytical Chemistry · doi:10.1021/ac981420y · Cited by 186
Microchip Devices for High-Efficiency Separations
Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M. (2000) · Analytical Chemistry · doi:10.1021/ac0006268 · Cited by 185
Herr, A. E., Molho, J. I., Drouvalakis, K. A., Mikkelsen, J. C., Utz, P. J., Santiago, J. G., & Kenny, T. W. (2003) · Analytical Chemistry · doi:10.1021/ac026239a · Cited by 185
Zhang, B., Foret, F., & Karger, B. L. (2000) · Analytical Chemistry · doi:10.1021/ac991150z · Cited by 168
Protein fractionation in a multicompartment device using Off‐Gel™ isoelectric focusing
Michel, P. E., Reymond, F., Arnaud, I. L., Josserand, J., Girault, H. H., & Rossier, J. S. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200390030 · Cited by 165
Self-citationCheng, S. B., Skinner, C. D., Taylor, J., Attiya, S., Lee, W. E., Picelli, G., & Harrison, D. J. (2001) · Analytical Chemistry · doi:10.1021/ac0007938 · Cited by 165
Zhang, S., Van Pelt, C. K., & Wilson, D. B. (2003) · Analytical Chemistry · doi:10.1021/ac034089d · Cited by 164
Enzyme linked immunosorbent assay on a microchip with electrochemical detection
Rossier, J. S., & Girault, H. H. (2001) · Lab on a Chip · doi:10.1039/b104772h · Cited by 164
Self-citationContinuous free‐flow electrophoresis
Křivánková, L., & Boček, P. (1998) · ELECTROPHORESIS · doi:10.1002/elps.1150190704 · Cited by 163
A Microchip-Based Enzyme Assay for Protein Kinase A
Cohen, C. B., Chin-Dixon, E., Jeong, S., et al. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4204 · Cited by 157
Microfabricated isoelectric focusing device for direct electrospray ionization-mass spectrometry
Wen, J., Lin, Y., Xiang, F., Matson, D. W., Udseth, H. R., & Smith, R. (2000) · Electrophoresis · Cited by 155
Unseen Proteome: Mining Below the Tip of the Iceberg To Find Low Abundance and Membrane Proteins
Pedersen, S. K., Harry, J. L., Sebastian, L. T., Baker, J., Traini, M. D., McCarthy, J. T., Manoharan, A., Wilkins, M. R., Gooley, A. A., Righetti, P. G., et al. (2003) · Journal of Proteome Research · doi:10.1021/pr025588i · Cited by 153
A Microfabricated Dialysis Device for Sample Cleanup in Electrospray Ionization Mass Spectrometry
Xu, N., Lin, Y., Hofstadler, S. A., Matson, D. W., Call, C. J., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac980233x · Cited by 150
Xiang, F., Lin, Y., Wen, J., Matson, D. W., & Smith, R. D. (1999) · Analytical Chemistry · doi:10.1021/ac981400w · Cited by 143
Microchip Injection and Separation Anomalies Due to Pressure Effects
Crabtree, H. J., Cheong, E. C. S., Tilroe, D., & Backhouse, C. (2001) · Analytical Chemistry · doi:10.1021/ac010217r · Cited by 138
Integrated Plastic Microfluidic Devices with ESI-MS for Drug Screening and Residue Analysis
Jiang, Y., Wang, P., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001474j · Cited by 137
Concentration and Separation of Proteins in Microfluidic Channels on the Basis of Transverse IEF
Macounová, K. M., Cabrera, C. R., & Yager, P. (2001) · Analytical Chemistry · doi:10.1021/ac001013y · Cited by 126
An Electrospray Ionization Source for Integration with Microfluidics
Kameoka, J., Orth, R. N., Ilic, B. R., Czaplewski, D. A., Wachs, T., & Craighead, H. G. (2002) · Analytical Chemistry · doi:10.1021/ac020396s · Cited by 123
SDS capillary gel electrophoresis of proteins in microfabricated channels
Yao, S. Q., Anex, D. S., Caldwell, W. B., Arnold, D. W., Smith, K. B., & Schultz, P. G. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.10.5372 · Cited by 121
Application of Microfluidic Devices to Proteomics Research
Li, J., LeRiche, T., Tremblay, T., Wang, C., Bonneil, É., Harrison, D. J., & Thibault, P. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m100022-mcp200 · Cited by 118
Electrophoretic Separation of Proteins on a Microchip with Noncovalent, Postcolumn Labeling
Liu, Y., Foote, R. S., Jacobson, S. C., et al. (2000) · Analytical Chemistry · doi:10.1021/ac000625f · Cited by 115
High-Throughput Microfabricated CE/ESI-MS: Automated Sampling from a Microwell Plate
Zhang, B., Foret, F., & Karger, B. L. (2001) · Analytical Chemistry · doi:10.1021/ac001432v · Cited by 112
Chip-Based Capillary Electrophoresis/Mass Spectrometry Determination of Carnitines in Human Urine
Deng, Y., Henion, J. D., Li, J., Thibault, P., Wang, C., & Harrison, D. J. (2001) · Analytical Chemistry · doi:10.1021/ac0009346 · Cited by 109
Sample pre-concentration by isotachophoresis in microfluidic devices
Wainright, A., Williams, S. J., Ciambrone, G., Xue, Q., Wei, J., & Harris, D. W. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01246-3 · Cited by 106
Polymer microchips bonded by O2-plasma activation
Wu, Z., Xanthopoulos, N., Reymond, F., et al. (2002) · Electrophoresis · doi:10.1002/1522-2683(200203)23:5<740::aid-elps740>3.0.co;2-7 · Cited by 102
Self-citationChan, J. H., Timperman, A. T., Qin, D., et al. (1999) · Analytical Chemistry · doi:10.1021/ac9906678 · Cited by 101
Integration of a microextraction system
Tokeshi, M., Minagawa, T., & Kitamori, T. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00683-x · Cited by 101
An integrated solid-phase extraction system for sub-picomolar detection
Jemere, A. B., Oleschuk, R. D., Ouchen, F., Fajuyigbe, F., & Harrison, D. J. (2002) · Electrophoresis · doi:10.1002/1522-2683(200210)23:20<3537::aid-elps3537>3.0.co;2-9 · Cited by 100
Polymer microchips bonded by O2-plasma activation
Wu, Z., Xanthopoulos, N., Reymond, F., Rossier, J. S., & Girault, H. H. (2002) · Electrophoresis · Cited by 100
Self-citationLiu, H., Felten, C., Xue, Q., Zhang, B., Jedrzejewski, P. T., Karger, B. L., & Foret, F. (2000) · Analytical Chemistry · doi:10.1021/ac000115l · Cited by 99
Lion, N., Gellon, J., Jensen, H. M., et al. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00771-4 · Cited by 95
Self-citationPeng, S. X., Branch, T. M., & King, S. L. (2000) · Analytical Chemistry · doi:10.1021/ac001036c · Cited by 92
Scaling issues in chemical and biological sensors
Madou, M. J., & Cubicciotti, R. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813577 · Cited by 83
Deng, Y., Zhang, H., & Henion, J. D. (2001) · Analytical Chemistry · doi:10.1021/ac0010328 · Cited by 82
Miniaturized capillary isoelectric focusing in plastic microfluidic devices
Tan, W., Fan, Z. H., Qiu, C. X., Ricco, A. J., & Gibbons, I. (2002) · Electrophoresis · doi:10.1002/1522-2683(200210)23:20<3638::aid-elps3638>3.0.co;2-y · Cited by 78
Becker, H., Lowack, K., & Manz, A. (1998) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/8/1/004 · Cited by 77
On-chip microextraction for proteomic sample preparation of in-gel digests
Ekström, S., Malmström, J. A., Wallman, L., Löfgren, M., Nilsson, J., Laurell, T., & Marko‐Varga, G. (2002) · PROTEOMICS · Cited by 73
Kim, J., & Knapp, D. R. (2001) · Electrophoresis · Cited by 72
On-line electrochemical tagging of cysteines in proteins during nanospray
Rohner, T. C., Rossier, J. S., & Girault, H. H. (2002) · Electrochemistry Communications · doi:10.1016/s1388-2481(02)00426-5 · Cited by 70
Self-citationBiomolecular Recognition on Well-Characterized Beads Packed in Microfluidic Channels
Buranda, T., Huang, J., Pérez-Luna, V. H., Schreyer, B., Sklar, L. A., & López, G. P. (2002) · Analytical Chemistry · doi:10.1021/ac0109624 · Cited by 66
Rossier, J. S., Youhnovski, N., Lion, N., Damoc, E., Becker, S., Reymond, F., Girault, H. H., & Przybylski, M. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390050 · Cited by 61
Self-citationJiang, Y., & Lee, C. S. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00718-x · Cited by 59
Bergkvist, J., Ekström, S., Wallman, L., Löfgren, M., Marko‐Varga, G., Nilsson, J., & Laurell, T. (2002) · PROTEOMICS · Cited by 48
Microfabrication of polydimethylsiloxane electrospray ionization emitters
Kim, J., & Knapp, D. R. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00901-3 · Cited by 47
Lion, N., Gobry, V., Jensen, H. M., Rossier, J. S., & Girault, H. H. (2002) · Electrophoresis · Cited by 47
Self-citationDynamic analyte introduction and focusing in plastic microfluidic devices for proteomic analysis
Li, Y., DeVoe, D. L., & Lee, C. S. (2003) · Electrophoresis · doi:10.1002/elps.200390013 · Cited by 43
Vreeland, W. N., Williams, S. J., Barron, A. E., & Sassi, A. P. (2003) · Analytical Chemistry · doi:10.1021/ac0259921 · Cited by 39
The interplay of biology and technology
Fields, S. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191380098 · Cited by 37
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Metadata
- Authors
- Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., Rossier, J. S., Przybylski, M., & Girault, H. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 24
- Issue
- 21
- Pages
- 3533-3562
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2053766086
- Cited by
- 262
- References
- 102
- FWCI
- 20.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.