Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,927

The DOI matches its Crossref record.

Blue silver: A very sensitive colloidal Coomassie G‐250 staining for proteome analysis

Candiano, Giovanni, Bruschi, Maurizio, Musante, Luca, Santucci, Laura, Ghiggeri, Gian Marco, Carnemolla, Barbara, Orecchia, Paola, Zardi, Luciano, Righetti, Pier Giorgio·2004·ELECTROPHORESIS

Abstract

A modified Neuhoff's colloidal Coomassie Blue G‐250 stain is reported, dubbed “blue silver” on account of its considerably higher sensitivity, approaching the one of conventional silver staining. The main modifications, as compared to Neuhoff's protocol, were: a 20% increment in dye concentration (from 0.1% up to 0.12%) and a much higher level of phosphoric acid in the recipe (from 2% up to 10%). The “blue silver” exhibits a much faster dye uptake (80% during the first hour of coloration, vs. none with a commercial preparation from Sigma). Even at equilibrium (24 h staining), the “blue silver” exhibits a much higher sensitivity than all other recipes, approaching (but lower than) the one of the classical silver stain. Measurements of stain sensitivity after sodium dodecyl sulfate‐polyacrylamide gel electrophoresis (SDS‐PAGE) of bovine serum albumin (BSA) gave a detection limit (signal‐to‐noise ratio > 3) of 1 ng in a single zone. The somewhat lower sensitivity of “blue silver” as compared to classical silvering protocols in the presence of aldehydes is amply compensated for by its full compatibility with mass spectrometry of eluted polypeptide chains, after a two‐dimensional map analysis, thus confirming that no dye is covalently bound (or permanently modifies) to any residue in the proteinaceous material. It is believed that the higher level of phosphoric acid in the recipe, thus its lower final pH, helps in protonating the last dissociated residues of Asp and Glu in the polypeptide coils, thus greatly favoring ionic anchoring of dye molecules to the protein moiety. Such a binding, though, must be followed by considerable hydrophobic association with the aromatic and hydrophobic residues along the polypeptide backbone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.200305844

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,927

Metadata

Authors
Candiano, G., Bruschi, M., Musante, L., Santucci, L., Ghiggeri, G. M., Carnemolla, B., Orecchia, P., Zardi, L., & Righetti, P. G.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2004-05
Volume
25
Issue
9
Pages
1327-1333
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2046726975
Cited by
1,927
References
0
FWCI
20.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blue silver: A very sensitive colloidal Coomassie G‐250 staining for proteome analysis. https://app.cochat.ai/papers/10.1002/elps.200305844
The paper
Candiano, G., Bruschi, M., Musante, L., Santucci, L., Ghiggeri, G. M., Carnemolla, B., Orecchia, P., Zardi, L., & Righetti, P. G. (2004). Blue silver: A very sensitive colloidal Coomassie G‐250 staining for proteome analysis. ELECTROPHORESIS. https://doi.org/10.1002/elps.200305844

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.