Recent advances in capillary separations for proteomics
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The sequencing of several organisms' genomes, including the human's one, has opened the way for the so‐called postgenomic era, which is now routinely coined as “proteomics”. The most basic task in proteomics remains the detection and identification of proteins from a biological sample, and the most traditional way to achieve this goal consists of protein separations performed by two‐dimensional polyacrylamide gel electrophoresis (2‐D PAGE). Still, the 2‐D PAGE‐mass spectrometry (MS) approach remains lacking in proteome coverage (for proteins having extreme isoelectric points or molecular masses as well as for membrane proteins), dynamic range, sensitivity, and throughput. Consequently, considerable efforts have been devoted to the development of non‐gel‐based proteome separation technologies in an effort to alleviate the shortcomings in 2‐D PAGE while reserving the ability to resolve complex protein and peptide mixtures prior to MS analysis. This review focuses on the most recent advances in capillary‐based separation techniques, including capillary liquid chromatography, capillary electrophoresis, and capillary electrokinetic chromatography, and combinations of multiples of these mechanisms, along with the coupling of these techniques to MS. Developments in capillary separations capable of providing extremely high resolving power and selective analyte enrichment are particularly highlighted for their roles within the broader context of a state‐of‐the‐art integrated proteome effort. Miniaturized and integrated multidimensional peptide/protein separations using microfluidics are further summarized for their potential applications in high‐throughput protein profiling toward biomarker discovery and clinical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Processing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Matrix Metalloproteinases as Modulators of Inflammation
MANICONE, A., & MCGUIRE, J. (2008) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2007.07.003 · Cited by 617
Kang, L., Chung, B. G., Langer, R., & Khademhosseini, A. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.003 · Cited by 325
Microfluidic Platforms for Single-Cell Analysis
Zare, R. N., & Kim, S. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105238 · Cited by 318
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Metadata
- Authors
- Cooper, J. W., Wang, Y., & Lee, C. S.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2004-12
- Volume
- 25
- Issue
- 23-24
- Pages
- 3913-3926
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2079187428
- Cited by
- 92
- References
- 3
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.