Microfluidic Platforms for Single-Cell Analysis
Abstract
Microfluidics, the study and control of the fluidic behavior in microstructures, has emerged as an important enabling tool for single-cell chemical analysis. The complex procedures for chemical cytometry experiments can be integrated into a single microfabricated device. The capability of handling a volume of liquid as small as picoliters can be utilized to manipulate cells, perform controlled cell lysis and chemical reactions, and efficiently minimize sample dilution after lysis. The separation modalities such as chromatography and electrophoresis within microchannels are incorporated to analyze various types of intracellular components quantitatively. The microfluidic approach offers a rapid, accurate, and cost-effective tool for single-cell biology. We present an overview of the recent developments in microfluidic technology for chemical-content analysis of individual cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Phylogenetic identification and in situ detection of individual microbial cells without cultivation
Amann, R., Ludwig, W., & SCHLEIFER, K. H. (1995) · Microbiological Reviews · doi:10.1128/mmbr.59.1.143-169.1995 · Cited by 9,093
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
The Uncultured Microbial Majority
Rappé, M. S., & Giovannoni, S. J. (2003) · Annual Review of Microbiology · doi:10.1146/annurev.micro.57.030502.090759 · Cited by 2,017
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Stochastic mRNA Synthesis in Mammalian Cells
Raj, A., Peskin, C. S., Tranchina, D., Vargas, D. Y., & Tyagi, S. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040309 · Cited by 1,737
Comprehensive human genome amplification using multiple displacement amplification
Dean, F. B., Hosono, S., Fang, L., Wu, X., Faruqi, A. F., Bray-Ward, P., Sun, Z., Zong, Q., Du, Y., Du, J., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082089499 · Cited by 1,467
Cited by
High-throughput microfluidic single-cell RT-qPCR
White, A. K., VanInsberghe, M., Petriv, O. I., Hamidi, M., Sikorski, D., Marra, M. A., Piret, J., Aparicio, S., & Hansen, C. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1019446108 · Cited by 440
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
The role of physiological heterogeneity in microbial population behavior
Lidstrom, M. E., & Konopka, M. C. (2010) · Nature Chemical Biology · doi:10.1038/nchembio.436 · Cited by 296
Transformer Hydrogels: A Review
Erol, O., Pantula, A., Liu, W., & Gracias, D. H. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900043 · Cited by 293
Metadata
- Authors
- Zare, R. N., & Kim, S.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2010-07
- Volume
- 12
- Issue
- 1
- Pages
- 187-201
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2161203530
- Cited by
- 318
- References
- 56
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic Platforms for Single-Cell Analysis. https://app.cochat.ai/papers/10.1146/annurev-bioeng-070909-105238
- The paper
- Zare, R. N., & Kim, S. (2010). Microfluidic Platforms for Single-Cell Analysis. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-070909-105238
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.