Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 234

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reduction of the concentration difference of proteins in biological liquids using a library of combinatorial ligands

Thulasiraman, Vanitha, Lin, Shanhua, Gheorghiu, Liliana, Lathrop, Julia, Lomas, Lee, Hammond, David, Boschetti, Egisto · 2005 · ELECTROPHORESIS

Abstract

The discovery of polypeptides and proteins with relevance to a particular biological state is complicated by their vast number and concentration range in most biological mixtures. Depletion methodologies are frequently used to remove the most abundant species; however, this removal not only fails significantly to enrich trace proteins, it may also nonspecifically deplete them due to their interactions with the removed high‐abundance proteins. Here we report a simple‐to‐use methodology that reduces the protein concentration range of a complex mixture like whole serum through the simultaneous dilution of high‐abundance proteins and the concentration of low‐abundance proteins. This methodology utilizes solid‐phase ligand libraries of immense diversity, generated by “split, couple, recombine” combinatorial chemistry, that are used for affinity‐based binding to the proteins of a given mixture. With a controlled sample‐to‐ligand ratio it is possible to modulate the relative concentration of proteins such that many peptides or proteins that are undetectable by classical analytical methods become easily accessible. The reduction in the dynamic range of unfractionated serum is specifically described along with treatment of other proteomes such as extracts from Escherichia coli, chicken egg white and cell culture supernatant. Mono‐ and bi‐dimensional electrophoresis (1‐DE and 2‐DE respectively) and surface‐enhanced laser desorption/ionization‐mass spectrometry (SELDI‐TOF‐MS) technology demonstrate the reduction in protein concentration range. Combining this approach with additional fractionation methods further increased the number of detectable species.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.200500147

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 234

Metadata

Authors
Thulasiraman, V., Lin, S., Gheorghiu, L., Lathrop, J., Lomas, L., Hammond, D., & Boschetti, E.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
2005-09
Volume
26
Issue
18
Pages
3561-3571
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2075823160
Cited by
234
References
1
FWCI
9.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.