The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Continuous separation of microparticles by size with Direct current‐dielectrophoresis
Abstract
Direct current‐dielectrophoresis (DC‐DEP), the induced motion of the dielectric particles in a spatially nonuniform DC electric field, is demonstrated to be a highly efficient method to separate the microparticles by size. The locally nonuniform electric field is generated by an insulating block fabricated inside a polydimethylsiloxane microchannel. The particle experiences a negative DEP (accordingly a repulsive force) at the corners of the block, where the local electric‐field strength is the strongest. Thus, the particle deviates from the streamline and the degree of deviation is dependent on the DEP force (i.e., the particle size). Combined with the electrokinetic flow, mixed polystyrene particles of a few micrometers difference in diameter can be continuously separated into distinct reservoirs. For separating target particles of a specific size, it is required to simply adjust the voltage outputs of the electrodes. A numerical model based on the Lagrangian tracking method is developed to simulate the particle motion and the results showed a reasonable agreement with the experimental data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786 · cited 2×
“The above formula is consistent with the conventional DEP force obtained by using the dipole-moment method [14].”
BackgroundMethod
Cited by
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Dielectrophoresis in microfluidics technology
Çetin, B., & Li, D. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100167 · Cited by 411
Self-citationGravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
DC-Dielectrophoretic separation of biological cells by size
Kang, Y., Li, D., Kalams, S. A., & Eid, J. E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9130-y · Cited by 276
Self-citationDielectrophoretic separation of bioparticles in microdevices: A review
Jubery, T. Z., Srivastava, S. K., & Dutta, P. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201300424 · Cited by 262
Metadata
- Authors
- Kang, K. H., Kang, Y., Xuan, X., & Li, D.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2006-02
- Volume
- 27
- Issue
- 3
- Pages
- 694-702
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2085847406
- Cited by
- 188
- References
- 1
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.