Capillary zone electrophoresis of glycopeptides under controlled electroosmotic flow conditions coupled to electrospray and matrix‐assisted laser desorption/ionization mass spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Defined conditions of EOF along with different pH values of the BGE were compared for the purpose of analyzing glycopetides by CZE coupled to MS (CZE‐MS). Hyphenation to MS involved ESI as well as MALDI, and single‐stage and multistage MS were applied. Variation of the EOF was accomplished by selecting appropriate coatings for the capillary, namely hexadimethrine bromide (HDMB) and HDMB/dextran sulfate. A high and reproducible anodic and cathodic EOF, respectively, was obtained in both approaches, allowing the detection of analytes with net positive as well as negative charge in one single run. Thus, a fast and sensitive determination of the glycopeptides in a tryptic digest of antithrombin, chosen as a test sample, was achieved. Ionization suppression effects, a phenomenon typically observed with glycopeptides in MS analysis, were minimized thanks to separation from other peptides present. The high stability of the coatings permitted the generation of mass spectra without interfering peaks originating from the coating polymers. The high EOF generated by the coatings facilitated the maintenance of a stable spray when coupling to ESI‐MS, and a stable CZE current when working with a sheath flow‐assisted analyte deposition onto MALDI targets, respectively. In conclusion, CZE‐MS could be demonstrated as a robust complementary method to capillary RP‐HPLC‐MS in combination with both soft‐ionization techniques, ESI and MALDI, generally, and particularly in the context of glycopeptide analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eukaryotic glycosylation: whim of nature or multipurpose tool?
Reuter, G., & Gabius, H.-J. (1999) · Cellular and Molecular Life Sciences (CMLS) · doi:10.1007/s000180050298 · Cited by 233
Cited by
Glycoproteomics based on tandem mass spectrometry of glycopeptides
Wuhrer, M., Catalina, M. I., Deelder, A. M., & Hokke, C. H. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.09.041 · Cited by 415
Mass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Mischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Giménez, E., Ramos‐Hernan, R., Benavente, F., Barbosa, J., & Sanz‐Nebot, V. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5114 · Cited by 36
Metadata
- Authors
- Amon, S., Plematl, A., & Rizzi, A.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2006-03
- Volume
- 27
- Issue
- 5-6
- Pages
- 1209-1219
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2057136123
- Cited by
- 46
- References
- 1
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.