The DOI matches its Crossref record.
Simul 5 – Free dynamic simulator of electrophoresis
Abstract
We introduce the mathematical model of electromigration of electrolytes in free solution together with free software Simul, version 5, designed for simulation of electrophoresis. The mathematical model is based on principles of mass conservation, acid–base equilibria, and electroneutrality. It accounts for any number of multivalent electrolytes or ampholytes and yields a complete picture about dynamics of electromigration and diffusion in the separation channel. Additionally, the model accounts for the influence of ionic strength on ionic mobilities and electrolyte activities. The typical use of Simul is: inspection of system peaks (zones), stacking and preconcentrating analytes, resonance phenomena, and optimization of separation conditions, in either CZE, ITP, or IEF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Advances in metabolite identification
Wishart, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.155 · Cited by 284
A review of the recent achievements in capacitively coupled contactless conductivity detection
Kubáň, P., & Hauser, P. C. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.11.045 · Cited by 253
Zhu, G., Sun, L., & Dovichi, N. J. (2016) · The Analyst · doi:10.1039/c6an01140c · Cited by 52
Metadata
- Authors
- Hruška, V., Jaroš, M., & Gaš, B.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2006-03
- Volume
- 27
- Issue
- 5-6
- Pages
- 984-991
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2144611033
- Cited by
- 182
- References
- 0
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simul 5 – Free dynamic simulator of electrophoresis. https://app.cochat.ai/papers/10.1002/elps.200500756
- The paper
- Hruška, V., Jaroš, M., & Gaš, B. (2006). Simul 5 – Free dynamic simulator of electrophoresis. ELECTROPHORESIS. https://doi.org/10.1002/elps.200500756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.