Rapid capillary electrophoresis time‐of‐flight mass spectrometry separations of peptides and proteins using a monoquaternarized piperazine compound (M7C4I) for capillary coatings
The DOI matches its Crossref record.
Abstract
A monoquaternarized piperazine, 1‐(4‐iodobutyl) 4‐aza‐1‐azoniabicyclo[2,2,2] octane iodide (M7C4I), has been evaluated as a surface derivatization reagent for CE in combination with TOF MS for the analysis of proteins, peptides, and protein digests. The M7C4I piperazine, at alkaline pH, forms a covalent bond via alkylation of the ionized silanols producing a cationic surface with a highly stable and reversed EOF. The obtained surface yields rapid separations (less than 5 min) of peptides and proteins at acidic pH with high separation efficiencies (up to 1.1×10 6 plates/m for peptides and up to 1.8×10 6 plates/m for proteins) and no observed bleeding of the coating reagent into the mass spectrometer. The simplicity of the coating procedure also enables fast (2 min) regeneration of the surface, if necessary. This is useful in the analysis of complex samples in order to prevent possible memory effects. The potential of using M7C4I‐coated capillaries for MS analysis of complex samples is demonstrated by the separation of peptides, proteins, and protein digests. Even more, the spectacular thing in which large intact proteins with molecular masses over 0.5 MDa could be separated. The coating showed good ability to handle these large proteins with high efficiency and retained peak shape as demonstrated by separation of IgG 1 (150 kDa) and thyroglobulin (669 kDa).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Belov, A. M., Zang, L., Sebastiano, R., Santos, M. R., Bush, D. R., Karger, B. L., & Ivanov, A. R. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201800067 · Cited by 88
Self-citationCE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
Sarg, B., Faserl, K., Kremser, L., Halfinger, B., Sebastiano, R., & Lindner, H. H. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.024109 · Cited by 76
“The separation capillaries were modified with three different coatings; one generated a non-charged inner capillary surface, and the other two generated positively charged surfaces (PEI and M7C4I).”
MethodInfluentialSelf-citationDada, O. O., Zhao, Y., Jaya, N., & Salas-Solano, O. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03405 · Cited by 20
Metadata
- Authors
- Elhamili, A., Wetterhall, M., Arvidsson, B., Sebastiano, R., Righetti, P. G., & Bergquist, J.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2008-04-17
- Volume
- 29
- Issue
- 8
- Pages
- 1619-1625
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2125420059
- Cited by
- 44
- References
- 0
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid capillary electrophoresis time‐of‐flight mass spectrometry separations of peptides and proteins using a monoquaternarized piperazine compound (M7C4I) for capillary coatings. https://app.cochat.ai/papers/10.1002/elps.200700737
- The paper
- Elhamili, A., Wetterhall, M., Arvidsson, B., Sebastiano, R., Righetti, P. G., & Bergquist, J. (2008). Rapid capillary electrophoresis time‐of‐flight mass spectrometry separations of peptides and proteins using a monoquaternarized piperazine compound (M7C4I) for capillary coatings. ELECTROPHORESIS. https://doi.org/10.1002/elps.200700737
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.