The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
2‐DE with IPGs
Abstract
In order to overcome the limitations of carrier ampholyte generated pH gradients, IPGs were developed in the late 1970s. However, the 2‐DE pattern we included in the first publication on IEF with IPGs [Bjellqvist et al., J. Biochem. Biophys. Methods 1982, 6, 317–339] was far from being competitive to O'Farrell's high‐resolution 2‐DE with carrier ampholytes. Our 2‐DE pattern in this article was, more or less, only a proof of principle. It was, however, the beginning of a long journey of stepwise improved 2‐DE protocols we developed in our laboratory and summarized in the reviews published in Electrophoresis 1988, 9, 531–546 and in Electrophoresis 2000, 21, 1037–1053. Milestones were the design of the IPG strip, and the “reduction‐alkylation equilibration protocol” of IPG strips after IEF for the efficient transfer of proteins from first to second dimension. The protocol of 2‐DE with IPGs has been constantly refined, e.g. by the generation of tailor‐made IPGs with different pH intervals from the acidic to the basic extremes (pH 2.5–12), and extended separation distances for improved resolution. In the present review, a historical outline from the technical difficulties encountered during the development of 2‐DE with IPGs, to the establishment of the actual “standard protocol” will be given, as well as the modified procedures for the separation of very acidic, very alkaline, low‐abundance and hydrophobic proteins, followed by a brief discussion of the advantages and technical challenges of gel‐based proteomic technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comprehensive mass-spectrometry-based proteome quantification of haploid versus diploid yeast
de Godoy, L. M. F., Olsen, J. V., Cox, J., Nielsen, M. L., Hubner, N. C., Fröhlich, F., Walther, T. C., & Mann, M. (2008) · Nature · doi:10.1038/nature07341 · Cited by 873
Cited by
Quantitation in Mass-Spectrometry-Based Proteomics
Schulze, W. X., & Usadel, B. (2010) · Annual Review of Plant Biology · doi:10.1146/annurev-arplant-042809-112132 · Cited by 344
Bulked sample analysis in genetics, genomics and crop improvement
Zou, C., Wang, P., & Xu, Y. (2016) · Plant Biotechnology Journal · doi:10.1111/pbi.12559 · Cited by 323
Plant secretome: Unlocking secrets of the secreted proteins
Agrawal, G. K., Jwa, N., Lebrun, M., Job, D., & Rakwal, R. (2010) · PROTEOMICS · doi:10.1002/pmic.200900514 · Cited by 311
Metadata
- Authors
- Görg, A., Drews, O., Lück, C., Weiland, F., & Weiss, W.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2009-06
- Volume
- 30
- Issue
- S1
- Pages
- S122-32
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2061843589
- Cited by
- 195
- References
- 1
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 2‐DE with IPGs. https://app.cochat.ai/papers/10.1002/elps.200900051
- The paper
- Görg, A., Drews, O., Lück, C., Weiland, F., & Weiss, W. (2009). 2‐DE with IPGs. ELECTROPHORESIS. https://doi.org/10.1002/elps.200900051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.