Decoupling CE and ESI for a more robust interface with MS
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An interface for CE‐ESI‐MS that decouples both the electrical and the solution flow rate requirements of the separation and ionization processes is presented. The interface uses a tapered and beveled stainless steel hollow needle surrounding the separation capillary terminus so that the inside of the electrode acts as the CE outlet vial and the outside tip acts as the electrospray emitter. No capillary pre‐treatment is required, enabling the use of capillaries with any type of surface modification. A chemical modifier solution is introduced through a second capillary connected to the needle via a tee junction and can be used to improve the compatibility of the CE BGE with electrospray. The flow rate of modifier solution can be as low as 0.1 μL/min, much less than that in a typical sheath‐flow interface, thus minimizing dilution of the CE effluent in order to maximize sensitivity. The presence of the modifier solution also allows the use of neutral‐coated capillaries for protein analysis by CE‐MS without using an assisting pressure, despite the absence of EOF under these conditions. The interface is easily integrated into a commercial CE instrument, such that all operations can be carried out by the automated controls. Compared with a commercial sheath‐flow CE‐MS interface operating under optimized conditions, LODs for amino acids were, on average, improved fivefold.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800480 · Cited by 45
Cited by
Mass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216
“Chen’s group reported a flow-through microvial interface in 2010[11], which has been used for metabolite,[12] glycan,[13] and intact protein[14] analysis.”
Belov, A. M., Viner, R., Santos, M. R., Horn, D. M., Bern, M., Karger, B. L., & Ivanov, A. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1781-1 · Cited by 97
CE‐MS for the analysis of intact proteins 2010–2012
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200439 · Cited by 96
CE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77
Metadata
- Authors
- Maxwell, E. J., Zhong, X., Zhang, H., van Zeijl, N., & Chen, D. D. Y.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2010-03-26
- Volume
- 31
- Issue
- 7
- Pages
- 1130-1137
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2163310011
- Cited by
- 150
- References
- 1
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.