New insight into suction and dilution effects in CE coupled to MS via an ESI interface. II – Dilution effect
Abstract
The hyphenation of CE with MS is nowadays accepted as a powerful analytical approach. As far as ESI, the most common interface, is concerned, one challenge is to provide the most sensitive as well as quantitative information, which is quite a difficult task, as it is linked, among other factors, to suction and dilution effects. In the coaxial ESI configuration, it has been previously demonstrated that suction effect depends on many parameters inherent to the ESI interface geometry, the prevailing ones being the CE capillary protrusion from the interface needle, the sheath liquid (SL) and the overall BGE flow rates and velocity profile. In this paper, dilution effect is studied, as the CE electrolyte is mixed with SL at the interface. Considering peak intensity and efficiency, this effect was studied as a function of the various parameters of the interface (capillary protrusion from the SL tube, nebulizing gas, SL and CE electrolyte flow rates) or of the source (skimmer and ESI voltages, drying gas flow rate and temperature). It appears that the dilution effect seems slightly lower than what can be anticipated from the proportions of the liquid flow rates. This study also indicates that suction effect has to be considered first to better understand the dilution phenomenon, as suction effect leads to an increase in peak intensity, before a dilution effect appears.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Suction effects caused by the sheath-liquid and nebulizing gas can be detrimental to separation efficiency.
“Also, suction effects that are caused by both the sheath-liquid and nebulizing gas can be detrimental for separation efficiency53.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [53]
Cites
Dole, M., Mack, L. L., Hines, R. L., et al. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,617 · see citing works
Electrospray interface for liquid chromatographs and mass spectrometers.
Whitehouse, C., Dreyer, R., Yamashita, M., & Fenn, J. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,368 · see citing works
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 801 · see citing works
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nhung, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635 · see citing works
Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry
Smith, R. D., Barinaga, C. J., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00169a022 · Cited by 534 · see citing works
Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface
Smith, R. D., Olivares, J. A., Nhung, N. T., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00156a013 · Cited by 393 · see citing works
Electrospray-ion spray: a comparison of mechanisms and performance
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00018a017 · Cited by 323 · see citing works
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · Electrophoresis · doi:10.1002/elps.1150181216 · Cited by 308 · see citing works
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · Electrophoresis · doi:10.1002/elps.200305659 · Cited by 290 · see citing works
Lee, E. D., Mück, W. M., Henion, J. D., & Covey, T. R. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90575-2 · Cited by 209 · see citing works
Characterization of an Electrospray Ion Source as a Controlled-Current Electrolytic Cell
Berkel, G. J. V., & Zhou, F. (1995) · Analytical Chemistry · doi:10.1021/ac00113a028 · Cited by 198 · see citing works
Molecular Beams of Macroions. II
Mack, L. L., Kralik, P., Rheude, A., et al. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1672733 · Cited by 155 · see citing works
Peer Reviewed: Advances in CE/MS.
Ding, J., & Vouros, P. (1999) · Analytical Chemistry · doi:10.1021/ac9904415 · Cited by 111 · see citing works
ICP-MS for specific detection in capillary electrophoresis
Álvarez‐Llamas, G., de laCampa, M. D. R. F., & Sanz‐Medel, A. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.09.007 · Cited by 103 · see citing works
Lawrenz, J., Obrebski, A., & Niemax, K. (1987) · Analytical Chemistry · doi:10.1021/ac00135a035 · Cited by 88 · see citing works
Shamsi, S. A., & Miller, B. E. (2004) · Electrophoresis · doi:10.1002/elps.200406131 · Cited by 78 · see citing works
Smyth, W. F. (2006) · Electrophoresis · doi:10.1002/elps.200500524 · Cited by 76 · see citing works
Moseley, M. A., Deterding, L. J., Wit, J. S. M. D., et al. (1989) · Analytical Chemistry · doi:10.1021/ac00189a021 · Cited by 76 · see citing works
Effects of nebulizing and drying gas flow on capillary electrophoresis/mass spectrometry
Huikko, K., Kotiaho, T., & Kostiainen, R. K. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.744 · Cited by 72 · see citing works
Mol, R., de Jong, G. J., & Somsen, G. W. (2004) · Electrophoresis · doi:10.1002/elps.200406101 · Cited by 71 · see citing works
Smyth, W. F. (2005) · Electrophoresis · doi:10.1002/elps.200406202 · Cited by 64 · see citing works
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2008) · Electrophoresis · doi:10.1002/elps.200700880 · Cited by 63 · see citing works
Self-citationWetterhall, M., Nilsson, S., Markides, K. E., & Bergquist, J. (2001) · Analytical Chemistry · doi:10.1021/ac010748f · Cited by 57 · see citing works
Tanaka, Y., Otsuka, K., & Terabe, S. (2002) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(02)00532-0 · Cited by 57 · see citing works
Huck, C. W., Bakry, R. S., Huber, L. A., & Bonn, G. K. (2006) · Electrophoresis · doi:10.1002/elps.200600046 · Cited by 53 · see citing works
Smyth, W. F., & Robledo, V. R. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.003 · Cited by 44 · see citing works
Analysis of bisphosphonates by capillary electrophoresis–electrospray ionization mass spectrometry
Huikko, K., & Kostiainen, R. K. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)01291-1 · Cited by 39 · see citing works
Muzikář, J., van de Goor, T., Gaš, B., & Kenndler, E. (2002) · Electrophoresis · doi:10.1002/1522-2683(200202)23:3 · Cited by 38 · see citing works
Schappler, J., Guillarme, D., Prat, J., Veuthey, J., & Rudaz, S. L. (2007) · Electrophoresis · doi:10.1002/elps.200700012 · Cited by 37 · see citing works
Use of DNase to eliminate contamination in ancient DNA analysis
Eshleman, J. A., & Smith, D. G. (2001) · Electrophoresis · doi:10.1002/1522-2683(200112)22:20 · Cited by 30 · see citing works
Tetler, L. W., Cooper, P. A., & Powell, B. B. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(94)01171-a · Cited by 25 · see citing works
Castro‐Puyana, M., García‐Ruiz, C., Cifuentes, A., et al. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.02.030 · Cited by 24 · see citing works
Analysis of benzalkonium chloride by capillary electrophoresis‐tandem mass spectrometry
Para, B. V., Núñez, Ó., Moyano, E., et al. (2006) · Electrophoresis · doi:10.1002/elps.200500716 · Cited by 20 · see citing works
Bezy, V., Chaimbault, P., Morin, P., et al. (2006) · Electrophoresis · doi:10.1002/elps.200500850 · Cited by 19 · see citing works
Single‐run separation of cationic, anionic, and polyanionic compounds by CE‐ESI‐MS
Mokaddem, M., Varenne, A., Belgaied, J., et al. (2007) · Electrophoresis · doi:10.1002/elps.200700176 · Cited by 11 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112 · see citing works
CE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86 · see citing works
CE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61 · see citing works
Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100461 · Cited by 48 · see citing works
Krenkova, J., & Foret, F. (2012) · PROTEOMICS · doi:10.1002/pmic.201200140 · Cited by 44 · see citing works
Bertoletti, L., Schappler, J., Colombo, R., Rudaz, S., Haselberg, R., Domínguez-Vega, E., Raimondi, S., Somsen, G. W., & De Lorenzi, E. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.010 · Cited by 25 · see citing works
- Authors
- Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- National Institute of Applied Science and Technology (TN)
- Corresponding author
- Varenne, Anne
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2009-05
- Volume
- 30
- Issue
- 10
- Pages
- 1692-1697
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2164320954
- Cited by
- 45
- References
- 36
- Citations by year
- 2026: 1 · 2022: 2 · 2021: 2 · 2020: 3 · 2019: 2 · 2018: 4 · 2017: 2 · 2016: 4 · 2015: 1 · 2014: 8 · 2013: 4 · 2012: 4
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Electrophoresis (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- capillary electrophoresis-mass spectrometry, dilution effect, suction effect, peak intensity, maximum efficiency
- MeSH terms
- Mass Spectrometry, Temperature, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review