CE‐ESI‐MS coupled with dynamic pH junction online concentration for analysis of peptides in human urine samples
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this article, an approach has been developed for the analysis of some small peptides with similar p I values by CE‐ESI‐MS based on the online concentration strategy of dynamic pH junction. The factors affected on the separation, detection and online enrichment, such as BGE, injection pressure, sheath flow liquid and separation voltage have been investigated in detail. Under the optimum conditions, i.e. using 0.5 mol/L formic acid (pH 2.15) as the BGE, preparing the sample in 50 mM ammonium acetate solution (pH 7.5), 50 mbar of injection pressure for 300 s, using 7.5 mM of acetic acid in methanol–water (80% v/v) solution as the sheath flow liquid and 20 kV as the separation voltage, four peptides with similar p I values, such as L‐Ala‐L‐Ala (p I=5.57), L‐Leu‐D‐Leu (p I=5.52), Gly‐D‐Phe (p I=5.52) and Gly‐Gly‐L‐Leu (p I=5.52) achieved baseline separation within 18.3 min with detection limits in the range of 0.2–2.0 nmol/L. RSDs of peak migration time and peak area were in the range of 1.45–3.57 and 4.93–6.32%, respectively. This method has been applied to the analysis of the four peptides in the spiked urine sample with satisfactory results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Cited by
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Zhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac5004486 · Cited by 78
Zhu, G., Sun, L., & Dovichi, N. J. (2016) · The Analyst · doi:10.1039/c6an01140c · Cited by 52
On‐line CE/ESI/MS interfacing: Recent developments and applications in proteomics
Krenkova, J., & Foret, F. (2012) · PROTEOMICS · doi:10.1002/pmic.201200140 · Cited by 44
Zhang, Z., Zhu, G., Peuchen, E. H., & Dovichi, N. J. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2084-8 · Cited by 24
Metadata
- Authors
- Ye, H., Xia, S., Lin, W., Yu, L., Xu, X., Zheng, C., Liu, X., & Chen, G.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2010-09-29
- Volume
- 31
- Issue
- 20
- Pages
- 3400-3406
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2129107507
- Cited by
- 25
- References
- 1
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CE‐ESI‐MS coupled with dynamic pH junction online concentration for analysis of peptides in human urine samples. https://app.cochat.ai/papers/10.1002/elps.201000194
- The paper
- Ye, H., Xia, S., Lin, W., Yu, L., Xu, X., Zheng, C., Liu, X., & Chen, G. (2010). CE‐ESI‐MS coupled with dynamic pH junction online concentration for analysis of peptides in human urine samples. ELECTROPHORESIS. https://doi.org/10.1002/elps.201000194
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.