The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hybrid microfluidics combined with active and passive approaches for continuous cell separation
Open accessAbstract
Microfluidics, which is classified as either active or passive, is capable of separating cells of interest from a complex and heterogeneous sample. Active methods utilise external fields such as electric, magnetic, acoustic, and optical to drive cells for separation, while passive methods utilise channel structures, intrinsic hydrodynamic forces, and steric hindrances to manipulate cells. However, when processing complex biological samples such as whole blood with rare cells, separation with a single module microfluidic device is difficult. Hybrid microfluidics is an emerging technique, which utilises active and passive methods whilst fulfilling higher requirements for stable performance, versatility, and convenience, including (i) the ability to process multi‐target cells, (ii) enhanced ability for multiplexed separation, (iii) higher sensitivity, and (iv) tunability for a wider operational range. This review introduces the fundamental physics and typical formats for subclasses of hybrid microfluidic devices based on their different physical fields; presents current examples of cell sorting to highlight the advantage and usefulness of hybrid microfluidics on biomedicine, and then discusses the challenges and perspective of future development and the promising direction of research in this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786 · cited 1×
“The net force FDEP is given by [26]: FDEP = 2 εmr (3)Re[K ( )]∇ERMS(2) (1)”
Cited by
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Tissue Engineering and Regenerative Medicine: Achievements, Future, and Sustainability in Asia
Han, F., Wang, J., Ding, L., Hu, Y., Li, W., Yuan, Z., Guo, Q., Zhu, C., Yu, L., Wang, H., et al. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00083 · Cited by 357
Self-citationParticle manipulations in non-Newtonian microfluidics: A review
Lu, X., Liu, C., Hu, G., & Xuan, X. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.04.019 · Cited by 289
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Metadata
- Authors
- Yan, S., Zhang, J., Yuan, D., & Li, W.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2016-10-27
- Volume
- 38
- Issue
- 2
- Pages
- 238-249
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2531142395
- Cited by
- 182
- References
- 1
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid microfluidics combined with active and passive approaches for continuous cell separation. https://app.cochat.ai/papers/10.1002/elps.201600386
- The paper
- Yan, S., Zhang, J., Yuan, D., & Li, W. (2017). Hybrid microfluidics combined with active and passive approaches for continuous cell separation. ELECTROPHORESIS. https://doi.org/10.1002/elps.201600386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.