The DOI matches its Crossref record.
Inelastic buildings with tuned mass dampers under moderate ground motions from distant earthquakes
Abstract
The effectiveness of tuned mass dampers (TMD) in vibration control of buildings was investigated under moderate ground shaking caused by long‐distance earthquakes with frequency contents resembling the 1985 Mexico City (SCT) or the 1995 Bangkok ground motion. The elastic–perfectly plastic material behaviour was assumed for the main structure, with linear TMDs employed by virtue of their simplicity and robustness. The accumulated hysteretic energy dissipation affected by TMD was examined, and the ratio of the hysteretic energy absorption in the structure with TMD to that without it is proposed to be used, in conjunction with the peak displacement ratio, as a supplementary TMD performance index since it gives an indication of the accumulated damage induced in the inelastic structures. For the ground motions considered, TMD would be effective in reducing the hysteretic energy absorption demand in the critical storeys for buildings in the 1.8–2.8 s range. The consequence is reduction in damage of the buildings which would otherwise suffer heavy damage in the absence of TMD, resulting in economical restorability in the damage control limit state. This is of practical significance in view of the current trend toward performance‐based design. Copyright © 2001 John Wiley & Sons, Ltd.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It was absorbed by the authors that over the building period range of 1.8-2.8s, the reduction in the dissipated energy is 40 per cent or more even though there is negligible reduction in the peak displacement response and TMD deteriorated in performance with increasing hysteretic energy dissipation.”
From Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review (2020) · cites this paper as Lukkunaprasit and Wanitkorkul [128]
In the citing paper
“It was absorbed by the authors that over the building period range of 1.8-2.8s, the reduction in the dissipated energy is 40 per cent or more even though there is negligible reduction in the peak displacement response and TMD deteriorated in performance with increasing hysteretic energy dissipation.”
From Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review (2020) · cites this paper as Lukkunaprasit and Wanitkorkul [128]
In the citing paper
“It was absorbed by the authors that over the building period range of 1.8-2.8s, the reduction in the dissipated energy is 40 per cent or more even though there is negligible reduction in the peak displacement response and TMD deteriorated in performance with increasing hysteretic energy dissipation.”
From Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review (2020) · cites this paper as Lukkunaprasit and Wanitkorkul [128]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- Kaynia AM, 1981, Seismic effectiveness of tuned mass dampers, Journal of Structural Division, ASCE, 107, 1465, 10.1061/JSDEAG.0005760 · DOI
- 10.1061/(ASCE)0733-9445(1983)109:8(2004) · DOI
- Den Hartog JP, 1956, Mechanical Vibrations
- ChowdhuryAH IwuchukwuMD GarskeJJ.The past and future of seismic effectiveness of tuned mass dampers. Proceedings of the 2nd International Symposium on Structural Control 1985;105–127. · DOI
- BernalD.Influence of ground motion characteristics on the effectiveness of tuned mass dampers. Proceedings of the 11th World Conference on Earthquake Engineering Acapulco Mexico 1996 paper no. 1455.
- 10.1002/eqe.4290070403 · DOI
- JaraJM AguiñigaF.Parametric study of a two degree of freedom system with resonant masses. Proceedings of the 11th World Conference on Earthquake Engineering Acapulco Mexico 1996 paper no. 1340.
- 10.1002/(SICI)1096-9845(199911)28:11<1255::AID-EQE865>3.0.CO;2-C · DOI
- Soong TT, 1997, Passive Energy Dissipation Systems in Structural Engineering, 245
- Newmark NM, 1959, A method of computation for structural dynamics, ASCE Journal of the Engineering Mechanics Division, 85, 67, 10.1061/JMCEA3.0000098 · DOI
- Chopra AK, 1995, Dynamics of Structures: Theory and Applications to Earthquake Engineering
- Gosain NK, 1977, Shear requirements for load reversals on RC members, Journal of Structural Division, ASCE, 103, 1461, 10.1061/JSDEAG.0004677 · DOI
Cited by
Sorted by citations
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
Zhang, Z., & Balendra, T. (2013) · Engineering Structures · doi:10.1016/j.engstruct.2013.03.044 · Cited by 56
Metadata
- Authors
- Lukkunaprasit, P., & Wanitkorkul, A.
- Affiliations
- Chulalongkorn University (TH)
- Corresponding author
- Lukkunaprasit, P.
- Venue
- Earthquake Engineering & Structural Dynamics
- Publisher
- Wiley
- Published
- 2001-01-30
- Volume
- 30
- Issue
- 4
- Pages
- 537-551
- ISSN
- 0098-8847 (ISSN-L)
- 1096-9845
- OpenAlex
- W1980665981
- Cited by
- 64
- References
- 0
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 9 · 2021: 1 · 2020: 3 · 2019: 3 · 2018: 5 · 2017: 6 · 2016: 3 · 2015: 3 · 2014: 1 · 2013: 1 · 2012: 2
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Earthquake Engineering & Structural Dynamics (publishedVersion)
- Funders
- Thailand Research Fund
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic Performance and Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic and Structural Analysis of Tall Buildings
- Keywords
- tuned mass damper, hysteretic energy dissipation, performance-based design, 1985 Mexico City earthquake, structural damage reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review