Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Open accessThe DOI matches its Crossref record; 164 of the 165 references it cites were found in a registry or an index; 6 of the 146 sources its claims cite were checked for support.
Abstract
This paper presents a critical review of active, passive, semi-active and hybrid control systems of TMD used for preserving structures against forces induced by earthquake or wind.
Overview
CoChat Summary
## TL;DR
This paper is a state-of-the-art review of tuned mass dampers (TMDs) and related passive, semi-active, active, and hybrid vibration control systems for structural vibration mitigation under wind and earthquake loading. It argues that active TMDs generally outperform passive TMDs in reducing structural response, while also identifying key research gaps such as uncertainty in tuning, nonlinear behavior, and soil-structure interaction.
## Key findings
- The review states that active TMDs have significantly better performance than passive TMDs, especially in reducing storey displacement; they also perform well when the excitation frequency is close to the structure’s fundamental frequency.
- The paper reports that single TMDs are the most commonly used and are often placed at the top floor; they work well for wind excitation in flexible structures but are less effective for earthquakes because they are tuned mainly to the dominant mode.
- It says multiple TMDs (MTMDs) can be more effective than a single TMD with equal mass and damping ratio and are less sensitive to parameter uncertainty; one cited study reports MTMD systems give an average 10% improvement in acceleration reduction over a single-TMD system, with similar displacement reduction.
- In bridge applications, the review notes that TMDs and MTMDs reduce responses such as buffeting and vibration; one cited study reports TMD use in a 101-storey building was materially effective in reducing wind-induced vibrations but not as effective for remote seismic vibrations.
## Methods
- This is a state-of-the-art literature review rather than an original experimental or numerical study.
- The paper synthesizes prior work on passive, semi-active, active, and hybrid TMD systems, including analytical formulations, numerical studies, experimental methods, optimization approaches, soil-structure interaction, and bridge applications.
- The analysis is a comparative narrative review of published studies, with some tabulated comparisons of system features and reported performance.
## Limitations
- The paper explicitly notes that previous review studies focused only on either passive or active TMDs, which this review seeks to address.
- The paper states that current practices in determining the principal natural frequency of TMDs need improvement and that more complex methods considering nonlinear behavior are needed to better predict structural response and optimize TMDs.
- Evident from the text: the review is qualitative and literature-based, so its conclusions depend on the scope and quality of the cited studies rather than on a new unified dataset or meta-analysis.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





![Figure 5 Mathematical model for TMD [93]](https://figures.cochat.ai/paper-figures/fe9c2275460941a4971196ecc03466a6/application-of-tuned-mass-dampers-for-structural-vibration-control-a-state-of-figure-5.png)
![Figure 6 Response and acceleration spectra of the primary structure under Northridge (Newhall-FN) earthquake [95]](https://figures.cochat.ai/paper-figures/50c9d537a9604143b2c0aed54c430126/application-of-tuned-mass-dampers-for-structural-vibration-control-a-state-of-figure-6.png)
![Figure 7 A shear structure with a VSDD brace control system [119]](https://figures.cochat.ai/paper-figures/a0158a6faad4452c9162b9ae559fe66d/application-of-tuned-mass-dampers-for-structural-vibration-control-a-state-of-figure-7.png)
![Figure 8 DMD (Distributed Mass Damper) system [120]](https://figures.cochat.ai/paper-figures/65197a4c7bc84a8cbf043d53af836a09/application-of-tuned-mass-dampers-for-structural-vibration-control-a-state-of-figure-8.png)

![Figure 10 The TMD implemented Structure including SSI effects [153]](https://figures.cochat.ai/paper-figures/038e1217814e4bc7ba8ff8d40b51b6bf/application-of-tuned-mass-dampers-for-structural-vibration-control-a-state-of-figure-10.png)
Verification
Claims the paper makes
5 Valid · 6 Not valid · 132 Not checked · 59 Own results and interpretations
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Pinelli and Gutierrez [58] showed that MTMDs effectively control the structural response during earthquakes of various periods and energy contents.”
§ Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review > 3.1.2. Multi TMD
What the sources say
- Could not verifycites Pinelli and Gutierrez [58] 58. Pinelli, J.-P. and H. Gutierrez. Experimental Study of Tuned Mass Dampers. In Proceedings of the US National Conference on Earthquake Engineering. 2002. Earthquake Engineering Research Institute. doi:10.1088/1742-6596/744/1/012045. sourceExperimental — accuracy not yet measured
Our copy of Wu, Qiong, Zhao & Xilu (2016) is an experimental study of a SINGLE passive tuned-mass damper on a 1:200 four-column jack-up offshore platform, tested under exactly two records (El-Centro NS 1940, M6.9; Taft EW 1952, M7.7) — see Abstract and Section 4 'Prototype Experiment'. No passage in the paper discusses multiple tuned-mass dampers (MTMD) or control 'during earthquakes of various periods and energy contents'; searches for 'MTMD / multiple tuned mass damper', 'Pinelli', 'Gutierrez' and 'energy content' returned nothing (the introduction mentions only double TMDs of Li et al. [11] in passing). On the contrary, Section 5.2 states 'a single damper, tuned to the fundamental mode, is adequate for reducing the structural vibration under earthquake excitations', and the paper does not cite Pinelli and Gutierrez at all, so the attributed finding cannot be checked here. (LLM, conf=0.72)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“Analytically shown that optimally designed TMDI outperforms the classical TMD in minimizing the displacement variance of un-damped singledegree-of-freedom (SDOF) white-noise excited primary structures.”
§ Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review > 3-TMD parameters reduce the displacement and acceleration responses significantly (50 percent).
What the sources say
- Supportedcites [77] 77. Marian, L. and A. Giaralis, Optimal Design of a Novel Tuned Mass-Damper-Inerter (Tmdi) Passive Vibration Control Configuration for Stochastically Support-Excited Structural Systems. Probabilistic Engineering Mechanics, 2014. 38: p. 156- 164. doi:10.1016/j.probengmech.2014.03.007. source
The Abstract (p. 3) states the claim directly. The concluding discussion (p. 29) also says that, for a fixed TMD mass, an optimally designed TMDI is more effective than a classical TMD at suppressing displacement variance in undamped SDOF structures under white-noise excitation. (LLM, conf=0.95)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“[156] experimentally demonstrated that performance of the TMD is optimum when the natural frequency of the TMD is tuned to the predominant modal frequency of the soil-structure system.”
§ Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review > 8. Soil-structure Interaction and TMD Performance
What the sources say
- Supportedcites [156] 156. Jabary, R.N. and G.S. Madabhushi, Tuned Mass Damper Positioning Effects on the Seismic Response of a Soil-Mdof- Structure System. Journal of Earthquake Engineering, 2018. 22(2): p. 281-302. doi:10.1016/j.soildyn.2015.06.013. source
The Conclusions report that centrifuge tests found tuning the TMD to the soil-structure system’s fundamental frequency more beneficial than tuning it to the fixed-base frequency. The Introduction also states the claimed optimum-tuning relationship, citing earlier shaking-table tests; this paper’s own tests support the same point. (LLM, conf=0.92)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
In the paper
“Hybrid control systems are effective to protect structures subjected to different types of excitation with dissimilar intensity and frequency range [13].”
§ Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review > 2.4. Hybrid Control Systems
What the sources say
- Not checked — no full text of the sourcecites [13] 13. Wu, S.-T., Y.-R. Chen, and S.-S. Wang, Two-Degree-of-Freedom Rotational-Pendulum Vibration Absorbers. Journal of Sound and Vibration, 2011. 330(6): p. 1052-1064. doi:10.1016/j.jsv.2010.09.028. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“Active control systems have been developed to enhance the capabilities of passive and semi-active systems in seismic structural response control [9].”
§ Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review > 2.3. Active Control Systems
What the sources say
- Not checked — no full text of the sourcecites [9] 9. Symans, M.D. and M.C. Constantinou, Semi-Active Control Systems for Seismic Protection of Structures: A State-of-the-Art Review. Engineering structures, 1999. 21(6): p. 469-487. doi:10.1016/S0141-0296(97)00225-3. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
94 more claims
Create a free account to see all 202 claims and to verify the 16 references still open.
- It may state two separate claims as one. 57
- Probably not a substantial claim. 66
- The quote only partly states this claim. 1
Citations
Cites
Chapter 12: What does the Anthropocene hold for citizenship?
(2019) · edoc (University of Basel) · doi:10.1007/978-3 · Cited by 11,533
Mechanical Vibrations: Applications to Equipment
Mori, Y. (2017) · Wiley eBooks · doi:10.1002/9781119384502 · Cited by 882
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828 · cited 4×
“[32] Giaralis, A. and A. Taflanidis, Optimal Tuned Mass‐Damper‐Inerter (TMDI) Design for Seismically Excited Mdof Structures with Model Uncertainties Based on Reliability Criteria.”
BackgroundInfluentialSemi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Parametric study and simplified design of tuned mass dampers
Rana, R., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00078-3 · Cited by 651 · cited 3×
“Rana and Soong [64] Parametric study and simplified design of TMD 1- When damping and mass ratio is increasing, the effect of detuning in TMDs parameters becomes less detrimental 2- During time-history analysis, when damping is getting large, TMD performance is reducing.”
BackgroundInfluentialJournal of Wind Engineering and Industrial Aerodynamics
Solari, G. (1998) · CINECA IRIS Institutial Research Information System (University of Genoa) · Cited by 636
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Soil-structure-interaction analysis in time domain
Wolf, J. P. (1989) · Nuclear Engineering and Design · doi:10.1016/0029-5493(89)90249-5 · Cited by 537 · cited 1×
“It is well known that the structural response is affected by soil flexibility owing to the effects of SSI [138].”
BackgroundArchives of Computational Methods in Engineering
(2013) · Archives of Computational Methods in Engineering · doi:10.1007/11831.1886-1784 · Cited by 529
Optimal tuned mass damper for seismic applications and practical design formulas
Hoang, N., Fujino, Y., & Warnitchai, P. (2008) · Engineering Structures · doi:10.1016/j.engstruct.2007.05.007 · Cited by 382
Research works printed but not linked: 9
- [57]57. Kamrani-Moghaddam, B., M. Rahimian, and A.K. Ghorbani-Tanha, Performance of Tuned Mass Dampers for Response Reduction of Structures under near-Field and Far-Field Seismic Excitations, in 4th International Conference on Earthquake Engineering. 2006: Taipei, Taiwan.
- [59]59. Lee, J., The Role of the Aerodynamic Modifications of the Shapes of Tall Buildings, 2011.Master's Thesis, Civil and Environmental Engineering, Massachusetts Institute of Technology, Massachusetts Available online: http://hdl.handle.net/1721.1/66869 (Accessed on: 9 Apr 2020).
- [131]131. Desu, N.B., S. Deb, and A. Dutta, Coupled Tuned Mass Dampers for Control of Coupled Vibrations in Asymmetric Buildings. Structural Control and Health Monitoring: The Official Journal of the International Association for Structural Control and Monitoring and of the European Association for the Control of Structures, 2006. 13(5): p. 897-916.
- [133]133. Islam, B. and R. Ahsan. Optimization of Tuned Mass Damper Parameters Using Evolutionary Operation Algorithm. in 15th World Conference in Earthquake Engineering (WCEE). 2012. Lisbon, Portugal.
- [134]134. Brock, J.E., A Note on the Damped Vibration Absorber. Trans. ASME, Journal of Applied Mechanics, A, 1946. 284.
- [139]139. Samali, B., K. Kwok, G. Young, and Y. Xu. Effectiveness of Optimised Tuned Liquid Column Dampers in Controlling Vibration of Tall Buildings Subject to Strong Ground Motions. In Proc. 2nd International Conf. on Highrise Buildings. 1992.
- [141]141. Chouw, N. Behaviour of Soil-Structure System with Tuned-Mass Dampers During near-Source Earthquakes. in 13th World Conference on Earthquake Engineering, Vancouver, BC, Canada. 2004.
- [146]146. Gao, H., B. Samali, and K. Kwok. Structural Vibration Control by Passive Dampers Considering Soil-Structure Interaction. in Proc. 2nd Int. Workshop on Structural Control, HJUST, Hong Kong. 1996.
- [155]155. Zoka, H. and S. Soheili, Tmd Effects on Drift for Earthquake Oscillations of Tall Building Including Soil Effects, in 2nd National Conference on New Material and Structures. 2018: Isfahan, Iran.
Cited by
Optimum Parameters of Tuned Inerter Damper for Damped Structures
Islam, N. U., & Jangid, R. S. (2022) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2022.117218 · Cited by 82
Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception
Konar, T., & Ghosh, A. (. (2024) · Structures · doi:10.1016/j.istruc.2024.106459 · Cited by 57
Train-induced vibration mitigation based on foundation improvement
Li, X., Chen, Y., Zou, C., et al. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107106 · Cited by 39
Experimental study on seismic retrofit of a RC frame using viscoelastic dampers
Nasab, M. S. E., Javidan, M. M., Chun, S., et al. (2021) · Structures · doi:10.1016/j.istruc.2021.08.044 · Cited by 36
Xu, S., Fang, G., Zhang, M., Øiseth, O. A., Zhao, L., & Ge, Y. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2023.110857 · Cited by 43
Metadata
- Authors
- Rahimi, F., Aghayari, R., & Samali, B.
- Affiliations
- Western Sydney University (AU)
- Razi University (IR)
- Venue
- Civil Engineering Journal
- Publisher
- Ital Publication
- Published
- 2020-08-01
- Volume
- 6
- Issue
- 8
- Pages
- 1622-1651
- ISSN
- 2476-3055 (ISSN-L)
- 2676-6957
- OpenAlex
- W3049331051
- Cited by
- 138
- References
- 163
- Citations by year
- 2026: 28 · 2025: 30 · 2024: 32 · 2023: 21 · 2022: 14 · 2021: 13
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Civil Engineering Journal (publishedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Vibration Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic and Structural Analysis of Tall Buildings
- Keywords
- tuned mass damper, structural vibration control, passive vibration control, active vibration control, semi-active vibration control, hybrid control systems, earthquake response, wind-induced vibration, high-rise buildings, vibration isolation, vibration absorber, natural frequency tuning, nonlinear structural response
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash and gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review. https://app.cochat.ai/papers/10.28991/cej-2020-03091571
- The paper
- Rahimi, F., Aghayari, R., & Samali, B. (2020). Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review. Civil Engineering Journal. https://doi.org/10.28991/cej-2020-03091571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.