Seismic response control of smart sliding isolated buildings using variable stiffness systems: an experimental and numerical study
The DOI matches its Crossref record.
Abstract
Effectiveness of a new semiactive independently variable stiffness (SAIVS) device in reducing seismic response of sliding base isolated buildings is evaluated analytically and experimentally. Through analytical and experimental study of force—displacement behaviour of the SAIVS device, it is shown that the device can vary stiffness continuously and smoothly between minimum and maximum stiffness. Passive sliding base isolation systems reduce interstorey drifts and superstructure accelerations, but with increased base displacements, which is undesirable, under large velocity near fault pulse type earthquakes. It is a common practice to incorporate non-linear passive dampers into the isolation system to reduce bearing displacements. Incorporation of passive dampers, however, may result in increased superstructure accelerations and drifts; while, properly designed passive dampers can be beneficial. A viable alternative is to use semiactive variable stiffness systems, which can vary the period of the sliding base isolated buildings in real time, to simultaneously reduce bearing displacements and superstructure responses further than the passive systems, which deserves investigation. This study investigates the performance of a 1:5 scaled smart sliding base isolated building model equipped with the SAIVS device analytically and experimentally, under near fault earthquakes, by developing a new moving average non-linear tangential stiffness control algorithm for control of the SAIVS device. The SAIVS device reduces bearing displacements further than the passive cases, while maintaining isolation level forces and superstructure responses at the same level as the passive minimum stiffness case, indicating the significant potential of the SAIVS system. Copyright © 2005 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Using an inerter‐based device for structural vibration suppression
Lazar, I. F., Neild, S. A., & Wagg, D. J. (2014) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2390 · Cited by 799
Adaptive Negative Stiffness: New Structural Modification Approach for Seismic Protection
Pasala, D. T. R., Sarlis, A. A., Nagarajaiah, S., Reinhorn, A. M., Constantinou, M. C., & Taylor, D. (2013) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0000615 · Cited by 284
Self-citationNagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
“It is the previous section it was shown in Equation (45) that the SAIVS device force fsvðtÞ 1⁄4 frðtÞ þ ff ðt; _ uÞ ð55Þ where frðtÞ 1⁄4 ke cos(2) yðtÞuðtÞ with ke being the stiffness of one of the four springs, yðtÞ is a timevarying angle of the spring elements with the horizontal, and ff being the frictional forces…”
BackgroundMethodSelf-citationVibration control performance of tuned mass dampers with resettable variable stiffness
Lin, G.-L., Lin, C.-C., Chen, B.-C., & Soong, T.-T. (2015) · Engineering Structures · doi:10.1016/j.engstruct.2014.10.041 · Cited by 77
Optimal PD/PID control of smart base isolated buildings equipped with piezoelectric friction dampers
Etedali, S., Sohrabi, M. R., & Tavakoli, S. (2013) · Earthquake Engineering and Engineering Vibration · doi:10.1007/s11803-013-0150-8 · Cited by 52
Kumar, P., Jangid, R. S., & Reddy, G. R. (2013) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2013.01.025 · Cited by 14
Metadata
- Authors
- Nagarajaiah, S., & Sahasrabudhe, S.
- Venue
- Earthquake Engineering & Structural Dynamics
- Publisher
- Wiley
- Published
- 2005
- Volume
- 35
- Issue
- 2
- Pages
- 177-197
- ISSN
- 0098-8847 (ISSN-L)
- 1096-9845
- OpenAlex
- W2059028407
- Cited by
- 138
- References
- 0
- FWCI
- 20.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.