Self‐centering structural systems with combination of hysteretic and viscous energy dissipations
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This paper presents an innovative set of high‐seismic‐resistant structural systems termed Advanced Flag‐Shaped (AFS) systems, where self‐centering elements are used with combinations of various alternative energy dissipation elements (hysteretic, viscous or visco‐elasto‐plastic) in series and/or in parallel. AFS systems is developed using the rationale of combining velocity‐dependent with displacement‐dependent energy dissipation for self‐centering systems, particularly to counteract near‐fault earthquakes. Non‐linear time‐history analyses (NLTHA) on a set of four single‐degree‐of‐freedom (SDOF) systems under a suite of 20 far‐field and 20 near‐fault ground motions are used to compare the seismic performance of AFS systems with the conventional systems. It is shown that AFS systems with a combination in parallel of hysteretic and viscous energy dissipations achieved greater performance in terms of the three performance indices. Furthermore, the use of friction slip in series of viscous energy dissipation is shown to limit the peak response acceleration and induced base‐shear. An extensive parametric analysis is carried out to investigate the influence of two design parameters, λ 1 and λ 2 on the response of SDOF AFS systems with initial periods ranging from 0.2 to 3.0 s and with various strength levels when subjected to far‐field and near‐fault earthquakes. For the design of self‐centering systems with combined hysteretic and viscous energy dissipation (AFS) systems, λ 1 is recommended to be in the range of 0.8–1.6 while λ 2 to be between 0.25 and 0.75 to ensure sufficient self‐centering and energy dissipation capacities, respectively. Copyright © 2010 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Somerville, P., Smith, N. F., Graves, R., & Abrahamson, N. (1997) · Seismological Research Letters · doi:10.1785/gssrl.68.1.199 · Cited by 1,611
Powell, G. H. (2008) · Earthquake Spectra · doi:10.1193/1.2932170 · Cited by 1,393
Displacement-based seismic design of structures
Calvi, G. M., & Kowalsky, M. J. (2007) · Cited by 1,076
Preliminary Results and Conclusions From the PRESSS Five-Story Precast Concrete Test Building
Priestley, M. J. N., Sritharan, S. (., Conley, J. R., & Stefano Pampanin, S. (1999) · PCI Journal · doi:10.15554/pcij.11011999.42.67 · Cited by 873 · cited 1×
“Structural damage and residual deformations (therefore repair cost) are minimized to negligible levels through the rocking mechanism and self-centering capabilities without any significant increase to peak responses, as shown in pseudo-dynamic testing [4, 5, 10] and numerical analyses [6, 11–13].”
BackgroundEffects of Fling Step and Forward Directivity on Seismic Response of Buildings
Kalkan, E., & Kunnath, S. K. (2006) · Earthquake Spectra · doi:10.1193/1.2192560 · Cited by 626 · cited 2×
“These peculiar 1 near-fault ground motions have been shown to cause significant displacement and ductility demand in structures as well as a possible amplification in inter-storey shear demand for both long and 3 short period conventional structures [20, 21].”
BackgroundPosttensioned Energy Dissipating Connections for Moment-Resisting Steel Frames
Christopoulos, C., Filiatrault, A., Uang, C.-M., & Folz, B. (2002) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2002)128:9(1111 · Cited by 538
Magnitude scaling of the near fault rupture directivity pulse
Somerville, P. G. (2003) · Physics of the Earth and Planetary Interiors · doi:10.1016/s0031-9201(03)00015-3 · Cited by 527 · cited 1×
“Furthermore, the current approach of amplification for near-fault effects has also been shown to be inconsistent with recorded strong ground motion data [19].”
BackgroundImplementation and testing of passive control devices based on shape memory alloys
Dolce, M., Cardone, D., & Marnetto, R. (2000) · Earthquake Engineering & Structural Dynamics · doi:10.1002/1096-9845(200007)29:7<945::aid-eqe958>3.0.co;2-# · Cited by 514 · cited 1×
“In addition, the concept has also been extended to different forms in which the self-centering capacity is derived not from un-bonded post-tensioning tendons, but from self-centering braces [30–32], Shape Memory Alloy (SMA) elements [33] and also in base isolation application [34].”
BackgroundEffect of viscous, viscoplastic and friction damping on the response of seismic isolated structures
Makris, N., & Chang, S.-P. (2000) · Earthquake Engineering & Structural Dynamics · doi:10.1002/(sici)1096-9845(200001)29:1<85::aid-eqe902>3.0.co;2-n · Cited by 294
Pampanin, S., Christopoulos, C., & Priestley, M. J. N. (2003) · Journal of Earthquake Engineering · doi:10.1080/13632460309350444 · Cited by 268
Self-citation
Cited by
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782
Metadata
- Authors
- Kam, W. Y., Pampanin, S., Palermo, A., & Carr, A. J.
- Venue
- Earthquake Engineering & Structural Dynamics
- Publisher
- Wiley
- Published
- 2010-07-27
- Volume
- 39
- Issue
- 10
- Pages
- 1083-1108
- ISSN
- 0098-8847 (ISSN-L)
- 1096-9845
- OpenAlex
- W2142474801
- Cited by
- 178
- References
- 14
- FWCI
- 15.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.